3-1540-2
Service Guide
Step 1
(from Step 3, 6, 7, 9, 10, 17)
1. Ensure that the diagnostics and the operating system are shut down.
2. Turn the key mode switch to the Service Position.
3. Sometimes an SRN or Error Code will be logged in the BUMP Error Log. Before
proceeding, check the BUMP Error Log for any SRNs or Error Codes. This is done as
follows:
a. Power off
b. Enable the BUMP Console Flag and disable the Autoservice IPL flag. This is done as
follows:
– Press Enter
– Type
sbb
and Press Enter
– Select Set Flags
Note: Ensure BUMP console is enabled and Autoservice is disabled.
– Exit the Standby menu.
c. Power on
d. When the Maintenance Menu appears, display the BUMP Error Log.
e. If an SRN is logged, record it and any location codes. Location Codes are separated
by a blank. Perform the listed action. An SRN will be preceded by 888 103.
f. If no SRN is logged, check for an Error Code. If an Error Code is logged, record it
and any location code. Location codes are separated by a blank. Perform the listed
action. Look up the Error Code for possible FRUs.
g. If nothing is logged, proceed to the next substep.
4. Set the power button on the CPU Enclosure to Off.
5. Unplug both PDB outlet power cords from both power supply power cords.
6. Plug both PDB outlet power cords into both power supply power cords.
7. Set the power button on the CPU Enclosure to On.
8. Insert the diagnostic CD-ROM disc into the CD-ROM drive.
9. Find the symptom in the following table that best matches the symptom on your system,
and then perform the associated task.
Summary of Contents for 7015-R30
Page 1: ...7015 Models R30 R40 and R50 CPU Enclosure Installation and Service Guide...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 34: ...1 20 Service Guide...
Page 214: ...6 10 Service Guide Detail 5 CPU Module 2 of 3 26 27 29 30 31 32 33 34 28 35...
Page 216: ...6 12 Service Guide Detail 6 CPU Module 3 of 3 36 37...
Page 252: ...B 8 Installation and Service Guide...
Page 288: ...Service Guide D 30...
Page 299: ......