4-48
Service Guide
Replacement
Notes:
Install the memory cards in a right-to-left sequence beginning with slot A, and then
continuing with slots B, C, and D. Memory cards must be installed with no empty
slots between installed memory cards.
Install the CPU cards in a right-to-left sequence beginning with slot P, and then
continuing with slots Q, R, and S. CPU cards must be installed with no empty slots
between installed CPU cards.
See “CPU Enclosure” on page 1-5 for card slot locations.
Replace in the reverse order.
For more information about memory cards and memory types, refer to Appendix C in the
Diagnostic Information For Micro Channel Bus Systems.
Summary of Contents for 7015-R30
Page 1: ...7015 Models R30 R40 and R50 CPU Enclosure Installation and Service Guide...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 34: ...1 20 Service Guide...
Page 214: ...6 10 Service Guide Detail 5 CPU Module 2 of 3 26 27 29 30 31 32 33 34 28 35...
Page 216: ...6 12 Service Guide Detail 6 CPU Module 3 of 3 36 37...
Page 252: ...B 8 Installation and Service Guide...
Page 288: ...Service Guide D 30...
Page 299: ......