4-78
Service Guide
I/O Planars
Note: Refer to “Handling Static-Sensitive Devices” on page 4-14 before removing or
installing the SIB.
Removal
1. Perform the “I/O Module” removal procedure on page 4-67.
2. Do the “Adapter” removal procedure on page 4-75 to remove all of the adapters installed
on the I/O planar you are removing.
3. To access the mounting screws on the I/O planars, disconnect both flex cable
connectors.
4. Disconnect the power cable connector from the rear of the I/O planar you are removing.
P13
Flex Cable Connectors
I/O Planars
P14
I/O Planar Power Cable
Connectors on I/O Planars
Note: Before removing the mounting screws, record the screw types and locations of all of
the mounting screws.
5. Remove the seven mounting screws on the I/O planar you are removing, and then
remove the I/O planar from the I/O module.
Mounting Screws (7)
Replacement
Replace in the reverse order.