Off Line Diagnostic Error Codes
D-5
Error
Number
Description
Failure
Percent
(%)
Failing
Function
Codes
Source
401-182
K
C59
Modem
20
80
Description: DIAL-OUT test. No customer Hub or Service Center
phone Dial-Out.
401-183
K
C59
Modem
20
80
Description: DIAL-OUT test. Modem parameters failed.
401-184
K
C59
Modem
20
80
Description: DIAL-OUT test. Line busy.
401-185
K
C59
Modem
20
80
Description: DIAL-OUT test. Connection Time out.
401-186
K
C59
Modem
20
80
Description: DIAL-OUT test. Modem answer failed.
401-187
K
C59
Modem
20
80
Description: DIAL-OUT test. Data Time out.
401-188
K
C59
Modem
20
80
Description: DIAL-OUT test. Data Carrier detect junction failed.
401-189
K
C59
Modem
20
80
Description: DIAL-OUT test. No data acknowledge.
401-190
K
C59
100
Description: BPP external Loop back. Data register error.
401-191
K
C59
100
Description: BPP external Loop back. Status register error.
401-400
K
C59
100
Description: JTAG chain integrity. Read IR failed.
401-401
K
C59
100
Description: JTAG chain integrity. Read DR failed: chip #.
401-501
K
C59
C63
C61
50
25
25
Description: Direct IO: IONIAN-SSGA.
Map register error
Action: Use MAP 0210.
401-502
K
C59
C63
C61
50
25
25
Description: Direct IO: IONIAN-SSGA.
CONFIGURATION register error.
Action: Use MAP 0210.
401-503
K
C59
C63
C61
50
25
25
Description: Direct IO: IONIAN-SSGA.
PERSONALIZE register error.
Action: Use MAP 0210.
401-509
K
C59
C63
C61
50
25
25
Description: Direct IO: IONIAN-SSGA.
POS3 register error.
Action: Use MAP 0210.
401-510
K
C59
C63
C61
50
25
25
Description: Direct IO: IONIAN-SSGA.
XIVR register error.
Action: Use MAP 0210.
401-511
K
C59
C63
C61
50
25
25
Description: Direct IO: IONIAN-SSGA.
DSIER register error.
Action: Use MAP 0210.
401-512
K
C59
C63
C61
50
25
25
Description: Direct IO: IONIAN-SSGA.
MFRR register error.
Action: Use MAP 0210.
401-513
K
C59
C63
C61
50
25
25
Description: Direct IO: IONIAN-SSGA.
BUID register error.
Action: Use MAP 0210.
Summary of Contents for 7015-R30
Page 1: ...7015 Models R30 R40 and R50 CPU Enclosure Installation and Service Guide...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 34: ...1 20 Service Guide...
Page 214: ...6 10 Service Guide Detail 5 CPU Module 2 of 3 26 27 29 30 31 32 33 34 28 35...
Page 216: ...6 12 Service Guide Detail 6 CPU Module 3 of 3 36 37...
Page 252: ...B 8 Installation and Service Guide...
Page 288: ...Service Guide D 30...
Page 299: ......