Off Line Diagnostic Error Codes
D-29
Understanding PKSR
The PKSR status is logged in hexadecimal value: 8 digits are logged. Each hexadecimal
digit must be converted in 4 binary digits: 32 bits are obtained. Divide the bits as indicated in
the PKSR layout and check the bit values to understand the meaning of the register.
Example
Suppose you receive an error message whose PKSR content in hex is:
9005 0007
converted to binary:
1001 000 0 0 0 0001 0 1 00000000 0000 0111
0 3 4 6 7 8 9 10 13 16 23 24 28 31 = Bit Numbering
This means that the following events occurred:
– fan1 fault
– a warning cooling message is displayed on the console
– the cooling system in operating in backup mode
– the key is in normal position
Summary of Contents for 7015-R30
Page 1: ...7015 Models R30 R40 and R50 CPU Enclosure Installation and Service Guide...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 34: ...1 20 Service Guide...
Page 214: ...6 10 Service Guide Detail 5 CPU Module 2 of 3 26 27 29 30 31 32 33 34 28 35...
Page 216: ...6 12 Service Guide Detail 6 CPU Module 3 of 3 36 37...
Page 252: ...B 8 Installation and Service Guide...
Page 288: ...Service Guide D 30...
Page 299: ......