3-1540-6
Service Guide
Step 4
(from Step 2)
No failure was detected with this configuration.
1. Set the power button on the CPU Enclosure to Off.
2. Unplug both PDB outlet power cords from both power supply power cords.
3. Starting with the CPU cards, install one additional CPU card (CPU) or memory card
(MC) (if any).
4. Plug both PDB outlet power cords into both power supply power cords.
5. Set the power button on the CPU Enclosure to On.
6. Wait for one of the following conditions to occur:
•
The Maintenance Menu is displayed.
•
The same three digit number is displayed in the operator panel display for longer than
three minutes except for the number
165
which may display for up to ten minutes with
no activity on the BUMP console.
•
The number
888
is flashing in the operator panel display.
Is the maintenance menu displayed?
NO
Go to Step 5.
YES
Repeat Step 4 until all CPU cards (CPU) and all memory cards (MC) are
installed and tested.
After all CPU cards (CPU) and all memory cards (MC) are installed and
tested, set the power button on the CPU Enclosure to Off and unplug both
PDB outlet power cords from both power supply power cords. Do the
following actions.
•
Install the SCSI adapter.
•
Connect the SCSI cable from the SCSI adapter to the SCSI connector
located above the disk drive.
•
Install the terminator on the connector DIFF. SCSI A on the system
interface board (SIB).
•
Go to Step 7, substep 5.
Summary of Contents for 7015-R50
Page 1: ...7015 Models R30 R40 and R50 CPU Enclosure Installation and Service Guide...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 34: ...1 20 Service Guide...
Page 214: ...6 10 Service Guide Detail 5 CPU Module 2 of 3 26 27 29 30 31 32 33 34 28 35...
Page 216: ...6 12 Service Guide Detail 6 CPU Module 3 of 3 36 37...
Page 252: ...B 8 Installation and Service Guide...
Page 288: ...Service Guide D 30...
Page 299: ......