3-1540-11
Maintenance Analysis Procedures (MAPs)
Step 9
(from Step 8)
1. Set the power button on the CPU Enclosure to Off.
2. Unplug both PDB outlet power cords from both power supply power cords.
3. Starting with the last installed adapter, disconnect one attached device and cable .
4. Insert the diagnostic CD-ROM disc into the CD-ROM drive.
5. Plug both PDB outlet power cords into both power supply power cords.
6. Set the power button on the CPU enclosure to On.
7. If the Maintenance Menu is displayed, select
System Boot
, then Boot From List.
8. If the system stops with a
260
displayed, and the Main Menu is displayed, Select
Exit
Main Menu and Start System (Boot)
and press Enter. When the “Starting
System Boot” menu displays, press Enter. Repeat this procedure each time these
conditions occur.
9. Wait for one of the following conditions to occur:
•
The system stops with
c31
displayed in the operator panel display.
•
The same three digit number is displayed in the operator panel display for longer than
three minutes except for the number
165
which may display for up to ten minutes with
no activity on the BUMP console.
•
The number
888
is flashing in the operator panel display.
Is
c31
displayed in the operator panel display
?
NO
Repeat Step 9 until the defective device or cable is identified or all the
devices and cables have been disconnected.
If all the devices and cables have been removed then, one of the FRUs
remaining in the CPU Enclosure is defective.
To test each FRU, exchange the FRUs in the following order:
1. Adapter (last one installed)
2. I/O card (IOC)
3. I/O planars
4. CPU module flex cables
5. I/O module flex cables
6. System interface board (SIB)
7. Power supply (PS)
If the symptom did not change and all the FRUs have been exchanged, call
your service support person for assistance.
If the symptom has changed, check for loose cards, cables, and obvious
problems. If you do not find a problem, return to Step 1 in this MAP, and
follow the instructions for the new symptom.
YES
The last device or cable you disconnected is defective.
Exchange the defective device or cable.
Go to “Map 0410: Repair Checkout” in the
Diagnostic Information For Micro
Channel Bus Systems.
Summary of Contents for 7015-R50
Page 1: ...7015 Models R30 R40 and R50 CPU Enclosure Installation and Service Guide...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 34: ...1 20 Service Guide...
Page 214: ...6 10 Service Guide Detail 5 CPU Module 2 of 3 26 27 29 30 31 32 33 34 28 35...
Page 216: ...6 12 Service Guide Detail 6 CPU Module 3 of 3 36 37...
Page 252: ...B 8 Installation and Service Guide...
Page 288: ...Service Guide D 30...
Page 299: ......