4-20
Service Guide
Operator Panel
Removal
1. Depending on the power distribution in your rack, do one of the following:
•
“Power-Off Procedure with a Power Distribution Bus” on page 4-2
•
“Power-Off Procedure with a Power Distribution Unit” on page 4-5
•
“Power-Off Procedure with a Power Distribution Panel” on page 4-9.
2. Do the “Front Bezel and Front Access Plate” removal procedure on page 4-15.
3. Remove the mounting screw attaching the operator panel to the CPU enclosure.
4. Pull the operator panel assembly toward you until it is out of the media module.
Operator Panel
Assembly
Front View of
CPU Enclosure
Mounting Screw
Replacement
1. Replace in the reverse order.
2. Depending on the power distribution in your rack, do one of the following Power-On
procedures:
•
“Power-On Procedure with a Power Distribution Bus” on page 4-4.
•
“Power-On Procedure with a Power Distribution Unit” on page 4-7.
•
“Power-On Procedure with a Power Distribution Panel” on page 4-11.