Service Guide
D-28
Power System Operating in Backup Mode
Bit 14 Values
Description
0
No power warning
1
Power system operating in backup mode warning
Cooling System Operating in Backup Mode
Bit 15 Values
Description
0
No cooling warning
1
Cooling system operating in backup mode warning
Power Fault and Fan Fault (R30, R40, and R50)
Bits 16–23 values
Description
00000000
No Interrupt
00000001
Over temperature level 1 on power supply #1
00000010
Over temperature level 2 on power supply #1
00000011
Internal power supply failure on power supply #1
00000100
Power supply #1 overload
00000101
Loss of primary power on power supply #1
00000110
Over temperature level 1 on power supply #2
00000111
Over temperature level 2 on power supply #2
00001000
Internal power supply failure on power supply #2
00001001
Power supply #2 overload
00001010
Loss of Primary power on power supply #2
00010000
Fan 1 fault
00100000
Fan 2 fault
00110000
Fan 3 fault
01000000
Fan 4 fault
01010000
Fan 5 fault
01100000
Fan 6 fault
01110000
Fan 7 fault
10000000
Fan 8 fault
10010000
Fan 9 fault
10100000
Fan 10 fault
Keylock Position
Bits 28–31 values
Description
0101
Secure
0110
Service
0111
Normal
Summary of Contents for 7015-R50
Page 1: ...7015 Models R30 R40 and R50 CPU Enclosure Installation and Service Guide...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 34: ...1 20 Service Guide...
Page 214: ...6 10 Service Guide Detail 5 CPU Module 2 of 3 26 27 29 30 31 32 33 34 28 35...
Page 216: ...6 12 Service Guide Detail 6 CPU Module 3 of 3 36 37...
Page 252: ...B 8 Installation and Service Guide...
Page 288: ...Service Guide D 30...
Page 299: ......