SSA Link Errors
|
SSA link errors can be caused if:
|
Power is removed from an SSA device
|
An SSA device is failing
|
An SSA device is removed
|
A cable is disconnected.
|
Such errors might be indicated by:
|
SRN 45PAA
|
A flashing link status (or Ready) light on the SSA device at each end of the failing link
|
The indication of an open link by the Link Verification Service Aid.
|
SSA Link Error Problem Determination
|
Instead of using the normal MAPs to solve a link error problem, you can refer directly to
|
the link status lights to isolate the failing FRU. The descriptions given here show you how
|
to do this.
|
In an SSA loop, SSA devices are connected through two or more SSA links to an SSA
|
adapter. Each SSA link is the connection between two SSA nodes (devices or adapters);
|
for example, disk drive module to disk drive module, adapter to disk drive module, or
|
adapter to adapter.
|
An SSA link can contain several parts. When doing problem determination, think of the
|
link and all its parts as one complete item.
|
Here are some examples of SSA links. Each link contains more than one part.
Chapter 2. Problem Determination Procedures
2-11
Summary of Contents for 7133 Series
Page 1: ...7133 SSA Disk Subsystems Service Guide SY33 0185 02...
Page 2: ......
Page 3: ...7133 SSA Disk Subsystems Service Guide SY33 0185 02...
Page 8: ...vi 7133 Service Guide...
Page 14: ...xii 7133 Service Guide...
Page 44: ...Labels Dummy Fan and Power Supply Assembly 1 30 7133 Service Guide...
Page 94: ...2 10 7133 Service Guide...
Page 110: ...2 2021 6 7133 Service Guide...
Page 114: ...2 2022 4 7133 Service Guide...
Page 138: ...2 2330 18 7133 Service Guide...
Page 146: ...2 16 7133 Service Guide...
Page 210: ...3 64 7133 Service Guide...
Page 222: ...4 12 7133 Service Guide...
Page 229: ......
Page 230: ...Part Number 32H6990 Printed in the United Kingdom 32H699 SY33 185 2...