Step 2
(from step 1)
Are you at this MAP because power is not removed completely from the 7133 when
the using system is turned off?
NO
Go to step 3.
YES
1. Check whether the 7133 has a Remote Power On Control feature installed
(see “Remote-Power-On Control Unit and Cables” on page 1-13).
If the feature is not installed, the using system has no control over the
supply of power to the 7133.
If the feature is installed, go to the next substep.
2. Ensure that the using-system power-control cables are correctly connected
to the remote-power-on control unit.
3. Go to step 6 on page 2-2030-5 in “MAP 2030: 7133 – Remote Power On
Control Feature.”
Step 3
(from step 2)
Have you been sent to this MAP from the Configuration Verification service aid?
NO
Go to step 4.
YES
Go to step 5 on page 2-2010-3.
Step 4
(from step 3)
Have you been sent to this MAP from the Link Verification service aid?
NO
Go to step 8 on page 2-2010-4.
YES
The SSA adapter has not found any pdisks that are in the “Available” state.
Either no disk drives are connected to the SSA adapter, or a loop configuration
that is not valid has been detected. See “SSA Subsystem Configurations” on
|
page 1-42 and the rules for SSA loops in the SSA Adapters: User’s Guide and
|
Maintenance Information manual.
2-2010-2
7133 Service Guide
Summary of Contents for 7133 Series
Page 1: ...7133 SSA Disk Subsystems Service Guide SY33 0185 02...
Page 2: ......
Page 3: ...7133 SSA Disk Subsystems Service Guide SY33 0185 02...
Page 8: ...vi 7133 Service Guide...
Page 14: ...xii 7133 Service Guide...
Page 44: ...Labels Dummy Fan and Power Supply Assembly 1 30 7133 Service Guide...
Page 94: ...2 10 7133 Service Guide...
Page 110: ...2 2021 6 7133 Service Guide...
Page 114: ...2 2022 4 7133 Service Guide...
Page 138: ...2 2330 18 7133 Service Guide...
Page 146: ...2 16 7133 Service Guide...
Page 210: ...3 64 7133 Service Guide...
Page 222: ...4 12 7133 Service Guide...
Page 229: ......
Page 230: ...Part Number 32H6990 Printed in the United Kingdom 32H699 SY33 185 2...