Solving Ethernet controller problems
Use this information to solve the Ethernet controller problems.
About this task
The method that you use to test the Ethernet controller depends on which
operating system you are using. See the operating-system documentation for
information about Ethernet controllers, and see the Ethernet controller
device-driver readme file.
Try the following procedures:
Procedure
1.
Make sure that the correct device drivers, which come with the server are
installed and that they are at the latest level.
2.
Make sure that the Ethernet cable is installed correctly.
v
The cable must be securely attached at all connections. If the cable is
attached but the problem remains, try a different cable.
v
If you set the Ethernet controller to operate at 100 Mbps, you must use
Category 5 cabling.
v
If you directly connect two servers (without a hub), or if you are not using a
hub with X ports, use a crossover cable. To determine whether a hub has an
X port, check the port label. If the label contains an X, the hub has an X port.
3.
Determine whether the hub supports auto-negotiation. If it does not, try
configuring the integrated Ethernet controller manually to match the speed and
duplex mode of the hub.
4.
Check the Ethernet controller LEDs on the rear panel of the server. These LEDs
indicate whether there is a problem with the connector, cable, or hub.
v
The Ethernet link status LED is lit when the Ethernet controller receives a
link pulse from the hub. If the LED is off, there might be a defective
connector or cable or a problem with the hub.
v
The Ethernet transmit/receive activity LED is lit when the Ethernet controller
sends or receives data over the Ethernet network. If the Ethernet
transmit/receive activity is off, make sure that the hub and network are
operating and that the correct device drivers are installed.
5.
Check the LAN activity LED on the rear of the server. The LAN activity LED is
lit when data is active on the Ethernet network. If the LAN activity LED is off,
make sure that the hub and network are operating and that the correct device
drivers are installed.
6.
Check for operating-system-specific causes of the problem.
7.
Make sure that the device drivers on the client and server are using the same
protocol.
8.
What to do next
If the Ethernet controller still cannot connect to the network but the hardware
appears to be working, the network administrator must investigate other possible
causes of the error.
Chapter 4. Troubleshooting
167
Summary of Contents for 7383
Page 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Page 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Page 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 479: ...Taiwan Class A compliance statement Notices 461 ...
Page 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 487: ......
Page 488: ... Part Number 46W8192 Printed in USA 1P P N 46W8192 ...