Table 39. IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only)”, that step must be performed only by a trained
technician.
806f0108-0a01ffff
806f0108-0a02ffff
The Power Supply
n
has failed. (
n
=
power supply
number)
Error
Power supply
n
has failed. (
n
=
power supply
number)
1.
Reseat power supply
n
.
2.
If the power-on LED is not lit and
the power-supply error LED is lit,
replace power supply
n
(see
Removing a hot-swap power
supply and Installing a hot-swap
power supply).
3.
If both the power-on LED and the
power-supply error LED are not lit,
see Power-supply LEDs for more
information.
(
n
= power supply number)
806f0109-1301ffff
System board 1 has
been turned off
Info
The compute node
has been powered
off.
No action; information only.
806f0308-0a01ffff
806f0308-0a02ffff
The Power Supply
n
has lost input. (
n
=
power supply
number)
Info
Power supply
n
AC has lost. (
n
=
power supply
number)
1.
Reconnect the power cords.
2.
Check power supply
n
LED.
3.
See Power-supply LEDs for more
information.
(
n
= power supply number)
80070208-0a01ffff
80070208-0a02ffff
Sensor PS
n
Therm
Fault has transitioned
to critical from a less
severe state. (
n
=
power supply
number)
Error
A sensor has
changed to Critical
state from a less
severe state.
1.
Make sure that there are no
obstructions, such as bundled
cables, to the airflow from the
power-supply fan.
2.
Use the IBM Power Configurator
utility to determine current system
power consumption. For more
information and to download the
utility, go to http://www.ibm.com/
systems/bladecenter/resources/
powerconfig.html.
3.
Replace power supply
n
.
(
n
= power supply number)
80070608-0a01ffff
80070608-0a02ffff
Sensor PS
n
12V
AUX Fault has
transitioned to
non-recoverable from
a less severe state. (
n
= power supply
number)
Error
A sensor has
changed to
non-recoverable
state from a less
severe state.
1.
Check power supply
n
LED.
2.
Replace power supply
n
.
(
n
= power supply number)
80070608-0a01ffff
80070608-0a02ffff
Sensor PS
n
12V OC
Fault has transitioned
to non-recoverable
from a less severe
state. (
n
= power
supply number)
Error
A sensor has
changed to
non-recoverable
state from a less
severe state.
1.
Use the IBM Power Configurator
utility to determine current system
power consumption. For more
information and to download the
utility, go to http://www.ibm.com/
systems/bladecenter/resources/
powerconfig.html.
406
System x3500 M4 Type 7383: Installation and Service Guide
Summary of Contents for 7383
Page 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Page 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Page 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 479: ...Taiwan Class A compliance statement Notices 461 ...
Page 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 487: ......
Page 488: ... Part Number 46W8192 Printed in USA 1P P N 46W8192 ...