Table 39. IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only)”, that step must be performed only by a trained
technician.
General messages
8007010f-2201ffff
Sensor TXT ACM
Module has
transitioned from
normal to non-critical
state.
Warning When TXT enabled
in Setup menu but
the startup BIOS
fails. Log an error.
1.
Ensure the TPM chip is enabled.
2.
(Trained technician only) Replace
the system board (see Removing the
system board and Installing the
system board).
80070114-2201ffff
Sensor TPM Phy Pres
Set has transitioned
from normal to
non-critical state.
Warning The TPM PP sensor
is a monitor on the
TPM device PP
pin's assertion.
There are two TPM
devices on the IBM
server, one is used
by uEFI /OS and
another is used by
IMM. When the
sensor is asserted ,
it means the TPM
device PP pin had
been pulled to low
state. This is a log
for user to know
the TPM device
had been cleared
and TPM owner
can be taken again.
1.
Complete the administrative tasks
that require the TPM physical
presence switch to be in the
ON
position.
2.
Restore the physical presence
switch to the
OFF
position.
3.
Reboot the system.
4.
(Trained technician only) If the
error continues, replace the
system-board assembly (see
Removing the system board and
Installing the system board).
80070202-0701ffff
Sensor SysBrd Vol
Fault has transitioned
to critical from a less
severe state.
Error
A sensor has
changed to Critical
state from a less
severe state.
1.
Check the system-event log.
2.
Check for an error LED on the
system board.
3.
Replace any failing device.
4.
Check for a server firmware update.
Important:
Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
5.
(Trained technician only) Replace
the system board (see Removing the
system board and Installing the
system board).
Appendix C. Integrated management module II (IMM2) error messages
437
Summary of Contents for 7383
Page 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Page 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Page 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 479: ...Taiwan Class A compliance statement Notices 461 ...
Page 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 487: ......
Page 488: ... Part Number 46W8192 Printed in USA 1P P N 46W8192 ...