v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 4, “Parts listing,” on page 41 to determine which components are customer replaceable units
(CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
Trained service technician.
Error code
Description
Action
2018002
Option Rom resource allocation failure.
1.
Run the Setup utility (see “Using the Setup
utility” on page 21). Select
Start Options
from
the menu and modify the boot sequence so that
you change the load order of the optional-device
ROM code.
2.
Run the Setup utility (see “Using the Setup
utility” on page 21) and disable unused resource
to make more space available:
v
Select
Start Options
v
Select
Planar Ethernet (PXE/DHCP)
to disable
the on-board Ethernet controller ROM.
v
Select
Advanced Functions
, followed by
PCI
Bus Control
, and then
PCI ROM Control
Execution
to disable the ROM of the adapters
in the PCI slots.
v
Select
Devices and I/O Ports
to disable any of
the on-board devices.
3.
If the problem remains, replace the following
components one at a time in the order shown,
restarting the server each time:
v
Expansion cards (see “Removing an I/O
expansion card” on page 71 and “Installing an
I/O expansion card” on page 75).
v
(Trained service technician only) Replace the
system board (see “Removing the
system-board assembly” on page 97 and
“Installing the system-board assembly” on
page 98).
158
BladeCenter HS22 Type 7870, 1936, and 1911: Problem Determination and Service Guide
Summary of Contents for 7870B4U
Page 1: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 14: ...xii BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 20: ...6 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 34: ...20 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 248: ...234 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 252: ...238 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 260: ...246 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 266: ...252 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 267: ......
Page 268: ...Part Number 90Y5614 Printed in USA 1P P N 90Y5614...