Memory problems
Use this information to diagnose and resolve memory problems with the blade
server.
Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
v
See Chapter 4, “Parts listing,” on page 41 to determine which components are CRUs and which components
are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom
Action
The amount of system memory
that is displayed is less than the
amount of installed physical
memory.
1.
Make sure that:
v
You have installed the correct type of memory (see “Installing a memory
module” on page 65).
v
If you changed the memory, you updated the memory configuration in the
Setup utility (see “Using the Setup utility” on page 21).
v
All banks of memory are enabled. The blade server might have
automatically disabled a memory bank when it detected a problem, or a
memory bank might have been manually disabled (see “Using the Setup
utility” on page 21).
2.
Check the IMM event log for a memory error (see “Viewing event logs
through the Setup utility” on page 103):
v
If a DIMM was disabled by a systems-management interrupt (SMI), replace
the DIMM (see “Removing a memory module” on page 64 and “Installing a
memory module” on page 65).
v
If a DIMM was disabled by the user or by POST, run the Setup utility and
enable the DIMM (see “Using the Setup utility” on page 21).
3.
Reseat the DIMM, and the optional expansion unit, if one is installed (see
“Removing a memory module” on page 64, “Installing a memory module” on
page 65, “Removing an optional expansion unit” on page 84, and “Installing
an optional expansion unit” on page 85).
4.
Replace the following components one at a time, in the order shown, restarting
the blade server each time:
a.
Optional expansion unit, if one is installed (see “Removing an optional
expansion unit” on page 84, and “Installing an optional expansion unit” on
page 85)
b.
DIMM (see “Removing a memory module” on page 64 and “Installing a
memory module” on page 65).
c.
(Trained service technician only) System-board assembly (see “Removing
the system-board assembly” on page 97 and “Installing the system-board
assembly” on page 98).
Multiple rows of DIMMs in a
branch are identified as failing.
1.
Make sure that the DIMMs are installed in the proper sequence (see “Installing
a memory module” on page 65).
2.
Reseat the DIMMs and restart the server (see “Removing a memory module”
on page 64 and “Installing a memory module” on page 65).
3.
Remove each DIMM one at a time, restarting the server after removing each
DIMM until the error is gone (see “Removing a memory module” on page 64).
4.
Replace the failed DIMM; then, reinstall the DIMMs to their original
connectors and restart the server (see “Installing a memory module” on page
65).
5.
(Trained service technician only) Replace the system board (see “Removing the
system-board assembly” on page 97 and “Installing the system-board
assembly” on page 98).
Chapter 6. Diagnostics
169
Summary of Contents for 7870B4U
Page 1: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 14: ...xii BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 20: ...6 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 34: ...20 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 248: ...234 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 252: ...238 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 260: ...246 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 266: ...252 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 267: ......
Page 268: ...Part Number 90Y5614 Printed in USA 1P P N 90Y5614...