Blade server light path diagnostics LEDs
Use this information to diagnose and resolve possible errors displayed by the light
path diagnostic LEDs.
The following table describes the LEDs on the light path diagnostics panels, on the
system board, and on the optional expansion unit and suggested actions to correct
the detected problems.
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 4, “Parts listing,” on page 41 to determine which components are CRUs and which components
are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Lit light path
diagnostics LED
Description
Action
None
An error has occurred and cannot be isolated,
or the service processor has failed.
1.
Make sure that the light path diagnostics
LED is lit, to ensure that there is enough
power in the blade server to light the rest
of the LEDs. See “Viewing the light path
diagnostics LEDs in the blade server” on
page 183.
2.
Check the BMC log for information about
an error that is not represented by a light
path diagnostics LED. See “Using the
Setup utility” on page 21.
Battery error
The system battery is not installed or is not
working.
1.
Reseat the battery. See “Removing the
battery” on page 58 and “Installing the
battery” on page 60.
2.
Replace the battery. See “Removing the
battery” on page 58 and “Installing the
battery” on page 60.
DIMM x error
A memory error occurred.
Look for system-event and IMM/AMM logs
related to memory and resolve those events
(see “IMM error messages” on page 105 and
“POST error codes” on page 146).
LP1
v
LP1 LED on system board: system-board
assembly light path diagnostic LEDs have
power.
v
LP1 LED on optional expansion unit: check
light path LEDs on the system board.
Check for error LEDs that are lit on the
system-board assembly. See “Viewing the light
path diagnostics LEDs in the blade server” on
page 183.
LP2
(optional
expansion unit
only)
Light path diagnostic LEDs on the optional
expansion unit have power.
Check for error LEDs that are lit on the
optional expansion unit. See “Viewing the
light path diagnostics LEDs in the blade
server” on page 183.
Chapter 6. Diagnostics
185
Summary of Contents for 7870B4U
Page 1: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 14: ...xii BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 20: ...6 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 34: ...20 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 248: ...234 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 252: ...238 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 260: ...246 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 266: ...252 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 267: ......
Page 268: ...Part Number 90Y5614 Printed in USA 1P P N 90Y5614...