v
See Chapter 4, “Parts listing,” on page 41 to determine which components are CRUs and which components
are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
166-905-xxx
Failed the IMM self test due to a failure in the
CPU/VRD bus.
Note:
Ignore this error if the direct access storage
device (DASD) planar is not installed.
1.
Turn off the blade server, open the blade server
release levers and pull the blade server away
from the blade server bay, but do not remove
it. See “Removing the blade server from the
BladeCenter unit” on page 52 for more
information.
2.
Wait 45 seconds and reseat the blade server in
the blade module bay and turn on the blade
server. See “Installing the blade server in a
BladeCenter unit” on page 53 and “Turning on
the blade server” on page 14.
3.
Rerun the test. See “Diagnostic tools overview”
on page 101.
4.
Make sure that the DSA Diagnostic code is
up-to-date, upgrade if necessary; then, rerun
the test. The latest code can be found on the
IBM support Web site at http://
www.ibm.com/systems/support/
supportsite.wss/docdisplay?brandind=5000008
&lndocid=MIGR-63017.
5.
Make sure that the IMM firmware level is
up-to-date, upgrade if necessary; then, rerun
the test. The installed firmware level can be
found in the DSA Diagnostic Event Log within
the Firmware/VPD section for this component.
The latest level firmware for this component
can be found on the IBM support Web site at
http://www.ibm.com/systems/support/
supportsite.wss/docdisplay?brandind=5000008
&lndocid=MIGR-63017.
6.
Turn off the blade server, remove the blade
server from the blade server bay and remove
the cover. (See “Removing the blade server
cover” on page 55 for more information).
7.
Locate the microprocessor and reseat it. (See
“Removing a microprocessor and heat sink” on
page 90 for more information.)
8.
Close the cover and reseat the blade server in
the blade server bay and turn on the blade
server.
9.
Rerun the test. See “Diagnostic tools overview”
on page 101.
10.
If the failure remains, refer to Chapter 5,
“Removing and replacing blade server
components,” on page 49 to replace the failed
component.
Chapter 6. Diagnostics
197
Summary of Contents for 7870B4U
Page 1: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 14: ...xii BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 20: ...6 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 34: ...20 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 248: ...234 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 252: ...238 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 260: ...246 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 266: ...252 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 267: ......
Page 268: ...Part Number 90Y5614 Printed in USA 1P P N 90Y5614...