Keyboard or mouse problems
Use this information to diagnose and resolve keyboard and mouse issues.
To check for keyboard or mouse problems, complete the following steps until the
problem is solved:
1.
Make sure that:
v
Both the blade server and the monitor are turned on.
v
The keyboard/video/mouse select button LED on the front of the blade
server is lit, indicating that the blade server is connected to the shared
keyboard and mouse.
v
The keyboard or mouse cable is securely connected to the active BladeCenter
Advanced Management Module.
v
The keyboard or mouse works with another blade server.
2.
Check for correct Advanced-Management-Module operation (see the
documentation for your BladeCenter unit).
Note:
Some BladeCenter unit types have several management-module
components that might have to be tested or replaced (see the
Installation Guide
for your Advanced Management Module for more information).
3.
Replace the keyboard or mouse.
4.
Replace the Advanced Management Module (see the documentation for your
BladeCenter unit).
If these steps do not solve the problem, it is likely a problem with the blade server.
See “Keyboard or mouse problems” on page 168.
Media tray problems
Use this information to diagnose and resolve media tray issues for the blade
server.
To check for problems with the media tray (removable media drives and USB
ports), complete the following steps until the problem is solved:
1.
Make sure that:
v
The media-tray select button LED on the front of the blade server is lit,
indicating that the blade server is connected to the shared media tray.
v
The media tray devices work with another blade server.
2.
Determine whether the problem affects more than one media tray component:
v
USB ports
v
Diskette drive
v
CD or DVD drive
3.
For problems that affect only a USB port:
a.
Make sure that the USB device is operational. If you are using a USB hub,
make sure that the hub is operating correctly and that any software that the
hub requires is installed. Connect the USB device directly to the USB port,
bypassing the hub, to check its operation.
b.
Reseat the following components:
1)
USB device cable
2)
Media tray cable (if applicable)
3)
Media tray
c.
Replace the following components one at a time, in the order shown,
restarting the blade server each time:
228
BladeCenter HS22 Type 7870, 1936, and 1911: Problem Determination and Service Guide
Summary of Contents for 7870B4U
Page 1: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 14: ...xii BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 20: ...6 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 34: ...20 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 248: ...234 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 252: ...238 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 260: ...246 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 266: ...252 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 267: ......
Page 268: ...Part Number 90Y5614 Printed in USA 1P P N 90Y5614...