Removing the blade server from the BladeCenter unit
Use these instructions to remove the blade server from the BladeCenter unit.
The following illustration shows how to remove a single-width type of blade
server or blade filler from a Type 8677 BladeCenter unit. The appearance of your
BladeCenter unit might be different; see the documentation for your BladeCenter
unit for additional information.
Attention:
v
To maintain proper system cooling, do not operate the BladeCenter unit without
a blade server, expansion unit, or filler module installed in each blade server
bay.
v
When you remove the blade server, note the blade-server bay number.
Reinstalling a blade server into a different blade server bay from the one it was
removed from can have unintended consequences. Some configuration
information and update options are established according to blade-server bay
number; if you reinstall the blade server into a different bay, you might have to
reconfigure the blade server.
To remove the blade server, complete the following steps:
1.
If the blade server is operating, shut down the operating system (see the
documentation for your operating system for more information).
2.
If the server is still on, press the power-control button for four seconds to turn
off the blade server (see “Turning off the blade server” on page 14 for more
information).
Attention:
Wait at least 30 seconds, until the storage devices stops spinning,
before you proceed to the next step.
3.
Open the two release handles as shown in the illustration. The blade server
moves out of the blade server bay approximately 0.6 cm (0.25 inch).
4.
Pull the blade server out of the bay.
Attention:
Two people are required to remove a Type 1911 blade server out of
the bay.
Statement 4: (for Type 1911)
52
BladeCenter HS22 Type 7870, 1936, and 1911: Problem Determination and Service Guide
Summary of Contents for 7870B4U
Page 1: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 14: ...xii BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 20: ...6 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 34: ...20 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 248: ...234 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 252: ...238 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 260: ...246 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 266: ...252 BladeCenter HS22 Type 7870 1936 and 1911 Problem Determination and Service Guide...
Page 267: ......
Page 268: ...Part Number 90Y5614 Printed in USA 1P P N 90Y5614...