background image

Leadership enterprise server with significantly lower cost of ownership in a highly available and 
expandable, rack-dense, 2U dual-socket server

 

Please see the Legal Information section for important notices and information. 

12 

you reduce both you total cost of ownership and the complexity that administrators and technical 
personnel face. 

IBM Systems Director Service and Support Manager

 (previously called IBM Electronic Service 

Agent

) is an innovative “call home” feature that allows System x and BladeCenter servers to 

automatically report hardware problems to IBM support, which can even dispatch onsite service if 
necessary to those customers entitled to onsite support under the terms of their warranty or an 
IBM Maintenance Agreement. Service and Support Manager resides on a server and provides 
electronic support and problem management capabilities through a highly secure electronic 
dialogue between your systems and IBM. It monitors networked servers for hardware errors and it 
can perform hardware and software inventories and report inventory changes to IBM. All 
information sent to IBM is stored in a highly secure database and used for improved problem 
determination. 

Additional services include hardware warranty upgrades and factory-installed 

Product 

Customization Services

 (PCS), such as asset tagging, hardware integration, software imaging 

and operating systems personalization. 

IBM offers extensive 

technical support

 by phone and via the Web. Support options include links 

to forums/newsgroups, problem submission, online shopping support, service offerings, device 
drivers for all IBM product lines, software downloads and even upcoming technical seminar 
worldwide schedules and registration. Also available are remote installation, configuration and 
usage support for System x hardware and software, as well as onsite custom services to provide 
the level of expertise you require. 

IBM Maintenance and Technical Support

 solutions can help you get the most out of your IT 

investment by reducing support costs, increasing availability and simplifying management with 
integrated support for your multiproduct, multivendor hardware and software environment. For 
more information on hardware maintenance, software support, solution support and managed 
support, visit 

http://

ibm.com

/services/maintenance

 

Advanced Systems Management Capabilities 

The x3650 M3 has a high level of systems management capabilities that are well-suited to remote 
locations as well as to stand-alone environments. Features include UEFI, IMM, IBM ToolsCenter, 
IBM Systems Director Active Energy Manager, Automatic Server Restart, Wake on LAN

®

 support, 

PXE support, text console redirect, Predictive Failure Analysis, and IBM Systems Director. 

The 

Integrated Management Module

 (

IMM

) provides industry-standard 

Intelligent Platform 

Management Interface

 (

IPMI

2.0

-compliant systems management. It provides a number of 

important system functions, including: 

  Monitoring of system and battery voltage, system temperature, fans, power supplies, processor 

and DIMM status 

  Fan speed control 

  Product ID and Family ID detection 

  Highly secure remote power on/off 

  System reset control 

  NMI/SMI detection and generation 

  System diagnostic LED control (power, HDD, activity, alerts, heartbeat) 

  IPMI over LAN 

  Serial Over LAN 

  Proxy server support 

  LAN messaging and alerting 

  Text console redirection over LAN 

  Predictive Failure Analysis for system fans 

  Web-based out-of-band control 

  SSL (Secure Socket Layer) and LDAP (Lightweight Directory Access Protocol) support 

  Enhanced authentication and encryption algorithms (RMCP+ and AES) 

  VLAN support 

  Local update of IMM firmware 

  Firmware firewall 

  Support for IPMI v2.0 compliant management software (e.g., xCAT) 

  Other mandatory and optional IPMI IMM functions 

The IMM alerts IBM Systems Director to anomalous environmental factors, such as voltage and 
thermal conditions—even if the server has failed. 

Summary of Contents for 7945D2U

Page 1: ...3MHz DDR3 memory or up to 12 DIMMs 48GB of UDIMM memory and provides Chipkill ECC Error Checking and Correcting protection for high performance and reliability For even higher levels of availability t...

Page 2: ...vers using the L5640 E5645 E5649 and 1333MHz X56xx processors support 2 DIMMs per channel 2DPC at 1333MHz running at 1 5V Optional 50GB solid state drives SSDs use only 2W of power per drive vs 9 10W...

Page 3: ...werful systems management features simplify local and remote management of the x3650 M3 The x3650 M3 includes an Integrated Management Module IMM to monitor server availability perform Predictive Fail...

Page 4: ...rt Serial over LAN enhanced authentication and encryption algorithms RMCP and AES and a firmware firewall Altitude and temperature controlled fans adjust to compensate for changing thermal characteris...

Page 5: ...I is capable of 6 4 5 86 or 4 8 GTps gigatransfers per second depending on the processor model Four core Xeon processors contain four complete processor cores 6 core processors similarly contain six c...

Page 6: ...ssors with memory The 1333MHz E56xx L5640 and X56xx processor models support up to 1333MHz memory clock speed and 2 DIMMs per channel 2DPC at 1333MHz with single rank and dual rank RDIMMs and UDIMMs r...

Page 7: ...mirroring enabled Note Due to the double writes to memory performance is affected Because the third channel is disabled with mirroring active there is no point in populating it with memory Mirroring...

Page 8: ...ts and one 5 25 inch bay for an optional DVD RW drive The bays support a combination of SATA and SAS HDDs as well as solid state drives SSDs Optionally a Tape Enablement Kit can be installed to suppor...

Page 9: ...f length One x8 low profile There is also a dedicated riser card in the x3650 M3 that provides a x8 PCIe connector wired with x4 lanes for an internal ServeRAID card Dual Port Gigabit Ethernet Control...

Page 10: ...as Calibrated Vectored Cooling The base server with one power supply includes 3 hot swap fan modules for redundant cooling Each module includes 2 back to back fans with counter rotating blades In add...

Page 11: ...ols and many components can be removed and replaced without tools including the CD RW DVD combo drive hot swap drives and PCIe adapters as well as the integrated ServeRAID card embedded hypervisor key...

Page 12: ...services to provide the level of expertise you require IBM Maintenance and Technical Support solutions can help you get the most out of your IT investment by reducing support costs increasing availabi...

Page 13: ...timer is not reset within five minutes it automatically triggers the ASR hardware which immediately restarts the server and logs an ASR event with IBM Systems Director These features are designed so t...

Page 14: ...l management capability is needed In those situations the Virtual Media Key not only offers powerful new features it does so without taking up a valuable PCI X or PCIe adapter slot instead using a ded...

Page 15: ...Slots Processor Socket ServeRAID Controller Gb Ethernet Adapter Slots Adapter Slots Processor Heat Sink Empty Hot Swap 2 5 HDD Bays Status Lights Pop Out Drop Down Light Path Diagnostics Panel Optical...

Page 16: ...4x J6x JCx 1 2 all other models Hyper Threading Technology supported Yes 2 threads per core 52x 54x 62x 72x 82x D4x H4x J4x J6x JCx L4x No 2x 22x 32x Turbo Boost Technology supported Yes 52x 54x 62x 7...

Page 17: ...y Hot swap SAS SATA also hot swap or simple swap SSD Integrated disk controller LSI 1068 of disk drives supported per port 1 Integrated RAID controller standard ServeRAID BR10il v2 no cache RAID 0 1 1...

Page 18: ...ply type AC or DC universal autoswitching hot swap Power supply standard 460W 12x 22x 32x 52x 62x D4x H4x 80 Plus Gold up to 92 efficient 675W J4x L4x 675W high efficiency 72x 82x 54x J6x JCx Up to 95...

Page 19: ...eplaceable with two x16 PCIe or two PCI X 133 slots Flexibility Large memory capacity Up to 192GB of registered DDR3 DIMMs in 18 DIMM slots Up to 16 2 5 inch hot swap SAS SATA HDDs or SSDs or simple s...

Page 20: ...ss chassis and toolless slide design integrated Cable Management Arm Server Comparison Chart The following table shows the suggested uses for the respective IBM System x rack optimized servers includi...

Page 21: ...he Windows logo are trademarks or registered trademarks of Microsoft Corporation Other company product and service names may be trademarks or service marks of others IBM reserves the right to change s...