2. Leave the server connected to power.
3. Slide the server out of the rack and remove the cover (see “Removing the
cover” on page 44). The LED near the failing fan will be lit.
Attention:
To ensure proper system cooling, do not remove the top cover for
more than 30 minutes during this procedure.
4. Lift the fan out of the server.
5. Replace the fan within 30 seconds (see “Installing a hot-swap fan”).
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 111.
Installing a hot-swap fan
The server comes with three replaceable double fans. For proper cooling, the
server requires that all three fans be installed at all times.
Attention:
To ensure proper server operation, if a fan fails, replace it within 30
seconds. Have a replacement fan ready to install as soon as you remove the failed
fan.
To install any of the three replaceable fans, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 38.
2. If you have not done so already, slide the server out of the rack and remove the
cover (see “Removing the cover” on page 44).
Attention:
To ensure proper system cooling, do not remove the top cover for
more than 30 minutes during this procedure.
3. Orient the new fan over its position in the fan bracket so that the connector on
the bottom aligns with the fan connector on the system board.
4. Align the vertical tabs on the fan with the slots on the fan cage bracket.
5. Push the new fan into the fan connector on the system board. Press down on
the top surface of the fan to seat the fan fully. Make sure that the amber LED
next to the fan connector on the system board is off.
92
System x3650 M2 Types 4199 and 7947: Installation and User’s Guide
Summary of Contents for 7947E3U
Page 1: ......
Page 2: ......
Page 3: ...System x3650 M2 Types 4199 and 7947 Installation and User s Guide...
Page 8: ...vi System x3650 M2 Types 4199 and 7947 Installation and User s Guide...
Page 16: ...xiv System x3650 M2 Types 4199 and 7947 Installation and User s Guide...
Page 40: ...24 System x3650 M2 Types 4199 and 7947 Installation and User s Guide...
Page 150: ...134 System x3650 M2 Types 4199 and 7947 Installation and User s Guide...
Page 168: ...152 System x3650 M2 Types 4199 and 7947 Installation and User s Guide...
Page 169: ......
Page 170: ...Part Number 81Y6111 Printed in USA 1P P N 81Y6111...