d. From the other side of the ServeRAID controller, insert and tighten the
screw to secure the interposer card to the ServeRAID controller.
8. Connect one end of the remote battery cable to the interposer card.
Attention:
To avoid damage to the hardware, make sure that you align the
black dot on the cable connector with the black dot on the connector on the
interposer card.
Do not force the remote battery cable into the connector.
9. Install the ServeRAID controller on the riser card (see “Installing a PCI
adapter” on page 53).
10. Install the PCI riser-card assembly in the server (see “Installing a PCI
riser-card assembly” on page 47).
11. Connect the remote battery cable to the battery carrier.
Attention:
To avoid damage to the hardware, make sure that you align the
black dot on the cable connector with the black dot on the connector on the
interposer card.
Do not force the remote battery cable into the connector.
102