background image

Leadership enterprise server with significantly lower cost of ownership in a highly available and 
expandable, rack-dense, 2U dual-socket server

 

Please see the Legal Information section for important notices and information. 

12 

  Other mandatory and optional IPMI IMM functions 

The IMM alerts IBM Systems Director to anomalous environmental factors, such as voltage and 
thermal conditions—even if the server has failed. 

The x3650 M2 also supports an optional IBM Virtual Media Key for additional systems 
management capabilities, including: 

  Graphical console redirection over LAN 

  Web-based out-of-band control 

  Windows “blue screen” capture 

  Remote virtual floppy and CD-ROM 

  High-speed remote redirection of PCI video, keyboard and mouse 

  SSL (Secure Socket Layer) and LDAP (Lightweight Directory Access Protocol) support 

IBM developed IBM 

Systems Director Active Energy Manager 

to put control of system power-

saving features at the fingertips of administrators. Active Energy Manager is designed to take 
advantage of new features, such as monitoring power usage and balancing the performance of 
the system according to available power input. It provides the ability to plan and predict power 
consumption based on your hardware configuration. It also helps enable you to reduce the 
infrastructure required for redundancy, by using fewer servers on smaller power feeds and 
potentially lowering your overall data center support costs. It does this by inventorying all 
components, then adding up the total power draw and tracking the usage. It also includes power 
management features to help administrators manage or reduce power usage. 

Automatic Server Restart

 (ASR) helps reduce downtime by restarting the server automatically 

in the event of a system lockup. ASR technology is a combination of hardware circuitry tied into 
the server’s system reset function and a device driver. As long as the server continues running, 
the ASR watchdog timer will keep being reset, but if the operating system crashes or the 
hardware freezes somehow the ASR software will be unable to reset the hardware timer. If the 
timer is not reset within five minutes, it automatically triggers the ASR hardware, which 
immediately restarts the server (and logs an ASR event with IBM Systems Director). These 
features are designed so that 

no more than five minutes can pass before the server is restarted

Wake on LAN

 permits the server to be remotely powered on if it has been shut off. Once 

powered up, the server can be controlled across the network, using the 

Preboot Execution 

Environment

 (PXE). 

Like Wake on LAN, PXE is system firmware. It enables software such as the optional 

IBM 

Remote Deployment Manager

 to take control of a system before the BIOS, operating system or 

applications are loaded (using Wake on LAN/PXE) and lets an administrator perform many low-
level tasks remotely that would otherwise require a visit to each system. These tasks may include 
such things as formatting a hard disk drive, updating system firmware, or deploying a Windows or 
Linux operating system.  

Text Console Redirection 

support allows the administrator to remotely view x3650 M2 text 

messages over serial or LAN. An optional upgrade to the Virtual Media Key adds graphical 
console redirection. 

Predictive Failure Analysis

 

(PFA)

 is designed to allow the system to detect impending failure of 

supported components (processors, memory, HDDs, voltage regulator modules (VRMs), power 
supplies, and fans) 

before

 actual failure, and alert the administrator through IBM Systems 

Director. This gives you the ability to 

replace

 the failing component 

before

 it fails, resulting in 

increased uptime. 

IBM Systems

 

Director 

software for advanced workgroup management is included with the 

x3650 M2. IBM Systems Director comes with a portfolio of tools, including 

IBM Systems 

Director Active Energy Manager

Service and Support Manager

, and others. 

System 

Availability

 (a no-charge download) and 

Capacity Manager 

(sold separately) are available as add-

ons for additional server management and increased availability. IBM Systems Director provides 
a single uniform graphical interface for all of these systems management functions. 

IBM Systems Director enables you to customize thresholds and monitor system components (for 
things like temperature, voltage regulation, etc.) to help maximize uptime. 

Key Options 

IBM options for System x servers help you take your servers to a 
higher level 

You rely on System x options to supply a complete solution for your business needs. Options 
help you create an optimized server system to meet your data protection, storage and availability 
needs. Every IBM option is designed and tested for peak performance and flexibility, helping to 
maximize your return on investment. The combination of System x servers and options lets you 
keep your fingers on the pulse of your e-business.

 

Processors 

— The Intel Xeon processor provides high clock rates, two or four cores, 64-bit 

Summary of Contents for 7947E5U

Page 1: ...power management The x3650M2 uses up to 16 DIMMs with 128GB of registered 1333MHz DDR3 memory with Chipkill ECC Error Checking and Correcting protection for high performance and reliability For even...

Page 2: ...0GB solid state drives SSD use only 2W of power per drive vs 9 10W for 2 5 inch HDDs This is as much as 80 less power than a 2 5 inch HDD would use with a corresponding reduction in heat output The x3...

Page 3: ...py and optical drive support Windows blue screen error capture LDAP and SSL support and remote redirection of PCI video text keyboard and mouse cKVM And it does all this without consuming a valuable a...

Page 4: ...essors allowing you to upgrade to a second processor as your business needs require The x3650 M2 offers a choice of processor clock rates memory access speeds and energy draw including 95W four core X...

Page 5: ...gistered Memory with Chipkill ECC Protection The x3650 M2 ships with registered double data rate III DDR 3 memory and provides Active Memory features including advanced Chipkill memory protection opti...

Page 6: ...rank DIMMs For instance a system populated with six 2GB dual rank DIMMs outperforms a system populated with six 2GB single rank DIMMs by 7 for SPECjbb2005 Dual rank DIMMs are also better than quad ra...

Page 7: ...s your business grows 2 5 inch Hot Swap SAS 7 200 RPMs 500GB 3 0TB maximum capacity 10 000 RPMs 73 4 146 8 300 or 500GB 3 0TB maximum 15 000 RPMs 73 4 or 146 8GB 1 76TB maximum 2 5 inch Hot Swap SATA...

Page 8: ...ere is no additional charge for this capability It also supports highly secure remote power management using IPMI 2 0 plus Wake on LAN and PXE Preboot Execution Environment flash interface Optional PC...

Page 9: ...lower operating costs The front of the server has an LED indicator light to show possible component failures If the front LED indicates an error condition by pressing a button on the front of the serv...

Page 10: ...and 6 cabling to considerably reduce the number of cables KVM switches and PDUs needed rather than increasing them If a server is removed or added no complicated rewiring is needed One cable connects...

Page 11: ...changes to IBM All information sent to IBM is stored in a highly secure database and used for improved problem determination Additional services include hardware warranty upgrades and factory install...

Page 12: ...tarted Wake on LAN permits the server to be remotely powered on if it has been shut off Once powered up the server can be controlled across the network using the Preboot Execution Environment PXE Like...

Page 13: ...second power supply for the x3650 M2 enables redundancy for hot swap power In addition its 92 efficient design helps lower your energy bill for power and cooling Virtual Media Key The x3650 M2 include...

Page 14: ...em x3650 M2 Images Front View Inside View Hot Swap Power Supplies USB Hypervisor Key Hot Swap HDD Bays Hot Swap Fan Packs 16 DIMM Slots Processor Processor ServeRAID Controller Gb Ethernet Adapter Slo...

Page 15: ...32x 44x 4Lx 56x 64x 66x 6 4Gtps 74x 76x 84x 86x 94x 96x of processors standard maximum 2 2 76x 86x 96x 1 2 all other models Internal L3 cache 4MB 1 x 4MB unified cache 12x 24x 34x 3Ax 8MB 1 x 8MB unif...

Page 16: ...ontroller ServeRAID BR10i RAID 0 1 1E 12x 24x 32x 34x 3Ax 44x 4Lx 56x ServeRAID M5014 256MB cache optional battery RAID 0 1 10 5 50 optional RAID 6 60 with SED 64x 66x ServeRAID M5015 512MB cache with...

Page 17: ...Server 2008 2008 R2 Microsoft Windows Server 2003 2003 R2 RHEL 4 32 64 bit without Xen RHEL 5 32 64 bit with and without Xen SLES 10 11 32 64 bit with and without Xen VMware ESX Server 4 0 ESXi Server...

Page 18: ...Active Energy Manager IBM Service and Support Manager Integrated Management Module IMM IPMI 2 0 compliance including highly secure remote power control Text console redirection systems management stan...

Page 19: ...PC 3 1 1 2 2 1 3 3 3 3 Modeling Simulation 2 1 1 1 3 1 3 2 3 3 High Performance DB 2 2 1 1 1 3 2 2 3 3 Business Intelligence 2 1 1 1 2 1 2 2 1 3 Search 3 1 1 1 2 1 3 3 1 2 Content 2 2 2 2 2 1 3 3 2 2...

Page 20: ...nd service names may be trademarks or service marks of others IBM reserves the right to change specifications or other product information without notice References in this publication to IBM products...