background image

A highly available and expandable, rack-dense, 1U dual-socket SMP server, for application 
serving in Web environments

 

 

 

Please see the Legal Information section for important notices and information. 

 

 

Disk Controllers 

All SAS-equipped x3550 models include an integrated 

Adaptec AIC9580W

 

Serial-Attach SCSI 

(SAS)

 controller. This controller supports up to 

four

 internal SAS LVD (low-voltage differential) 

drives. SATA models have a separate SATA controller, which supports up to two internal SATA 
drives. 

The integrated 

ServeRAID-8k-l

 controller offers 

hardware

 

RAID-0

/

1/10

 support and 

32MB

 of fast 

PC2-4200

 

DDR2

 cache for the SAS drives. The 

ServeRAID-8k

 option adds 

three

 additional 

RAID levels, 

RAID-1E, 5 

and

 6

, along with 

256MB

 of cache memory for higher performance, and 

battery backup, 

without

 consuming a valuable adapter slot.  

The 

SAS

 controller provides data transfer speeds of up to 

300MB

 per second

5

 in 

each

 direction 

(

full-duplex

) across the SAS bus, for an aggregate speed of 

600MBps

, nearly double that of 

Ultra320 SCSI’s 

320MBps

 (half-duplex) bandwidth. The serial design of the SAS bus allows 

maximum performance to be maintained as additional drives are added. 

The 

SATA 

controller integrated in the SATA models supports up to 

two

 internal SATA II drives, 

with maximum data transfer rates of up to 

300MB

 (half-duplex) per second. This is throughput is 

similar to that of Ultra320 SCSI (

320MBps

, half-duplex). The SATA models also include firmware 

support for 

RAID-0/1

. The system can be upgraded to 

hardware

-based 

RAID-0/1/10/1E/5/6

 for 

higher performance, using the same IBM 

ServeRAID-8k SAS/SATA

 controller as the hot-swap 

server models. 

For external storage, the 

MegaRAID 8480

 controller enables connection to up to 

four

 IBM 

System Storage 

EXP3000

 SAS expansion units (

48

 HDDs total). It provides 

RAID-0/1/10/5/50

 

support and 

256MB

 of onboard cache. 

Additional external storage is available using one of several supported direct-attach, iSCSI or 
SAN controllers.

 

 

Large HDD Storage Capacity 

The x3550 offers a choice of disk storage, supporting up to 

two

 (

3.5

-inch) or 

four

 (

2.5

-inch) 

hot-

swap

 high-performance 

SAS

 drives, or 

two

 (

3.5

-inch) 

simple-swap SATA

 drives: 

3.5-inch SAS 

 

15,000

 RPMs — 73.4, 

146.8 

or

 300GB 

(

600GB maximum

)

 

2.5-inch SAS 

 

10,000

 RPMs — 73.4 or 

146.8GB 

(

587.2GB

)

 

 

15,000

 RPMs — 

73.4GB (293.6GB) 

3.5-inch SATA 

 

7,200

 RPMs — 160, 250, 500, 750GB or 

1TB 

(

2.0TB

)

 

2-5-inch drives not only require less space than 3.5-inch drives, they 

weigh less, consume half 

the power, produce less noise, seek faster,

 and offer 

increased reliability

Simple-swap SATA drives are 

not

 hot-swappable (the system must first be powered off); 

however, no tools or jumpers are required for installation and removal, allowing for faster, simpler 
servicing than fixed drives.

 

The hot-swap SAS drives use the Converged Tray for 

interchangeability with other IBM System x

 systems. If you need more storage space, terabyte 

capacities are possible with external direct-attach, NAS and SAN solutions.

 

 

High-Performance Adapter Slots 

The x3550 provides 

two x8

 (“by 8”) 

4GBps

 

PCI-E (PCI Express)

 adapters standard. Each is 

capable of supporting 

x1/x4/x8

 adapters at full speed.

 

Both slots are 

half-length/full-height

. If 

desired, the riser card containing slot 

2

 may optionally be replaced with one that provides 

one

 

half-length/full-height 

(1GBps) 

133MHz PCI-X

 slot instead. 

PCI-Express

 is a high-performance, low-latency, next-generation serial I/O bus that is rapidly 

replacing the older parallel PCI and PCI-X buses. A 

x8

 PCI-E adapter offers approximately 

four 

times

 the maximum throughput of a 133MHz PCI-X adapter

6

. (A 

x1

 adapter offers throughput 

similar to a 

66MHz

 PCI-X slot.) 

Because the 

SAS

ServeRAID-8k 

and 

8k-l

, dual 

Gigabit Ethernet

systems management

 and 

video

 controllers are integrated onto the system board, the two adapter slots are both 

available

which offers a wide degree of latitude in expansion options.

 

                                                

 

5

 Data transfer rates depend on many factors and are often less than the maximum possible. 

Summary of Contents for 79784AU

Page 1: ...nch simple swap Serial ATA II The integrated SAS controller provides hardware based RAID 0 1 10 standard for SAS drives SATA models offer firmware based RAID 0 1 support standard Additional RAID suppo...

Page 2: ...es The integrated dual Gigabit Ethernet controllers with IPMI 2 0 support provide high speed network communications Jumbo Frames offer higher efficiency transfers for large data packets The TCP Offloa...

Page 3: ...x3550 servers use Chipkill enabled fully buffered memory DIMMs Chipkill memory is up to 16X better than standard ECC memory at correcting memory errors This can help reduce downtime caused by memory...

Page 4: ...d core processors similarly contain four cores Some processors contain one unified cache shared by all cores while other processors have multiple independent caches one per pair of cores The shared ca...

Page 5: ...MMs one pair per memory channel Up to 16GB four 4GB DIMMS of memory is available for use with mirroring enabled Note Due to the double writes to memory performance is affected When online hot spare me...

Page 6: ...is available using one of several supported direct attach iSCSI or SAN controllers Large HDD Storage Capacity The x3550 offers a choice of disk storage supporting up to two 3 5 inch or four 2 5 inch...

Page 7: ...ns to reduce the ambient noise reduce the wear and tear on the fans and reduce the server power draw The reduction in ambient noise and power draw may be relatively minor for a single server but put d...

Page 8: ...ack Cable Management and KVM Console Switching IBM Advanced Cabling Technology ACT is an optional feature that offers many advantages over standard KVM cabling across the entire System x and xSeries p...

Page 9: ...he automated installation of the Microsoft Windows Server 2000 and 2003 operating systems device drivers and other system components with minimal user intervention Drivers are also included for suppor...

Page 10: ...em according to available power input It provides the ability to plan and predict power consumption based on your hardware configuration It also helps enable you to reduce the infrastructure required...

Page 11: ...ch processor Adding a second processor may be a cost effective way to achieve significant performance improvements Memory Memory is a significant factor in systems application performance Adding more...

Page 12: ...rage is available using one of several IBM System Storage and TotalStorage host bus adapters Additionally external LAN attached tape storage is available The iSCSI HBA Adapter for IXA Connectivity is...

Page 13: ...460 B7X B7Y BGX BGY Quad core Xeon E53xx L53xx 1 6GHz L5310 JAX JAY 1 86GHz L5320 JBX JBY Dual core Xeon 51xx 1 6GHz 5110 2xX 2xY 2 33GHz 5140 5xX 5xY 3 0GHz 5160 7xX 7xY Maximum processor power draw...

Page 14: ...ble 1 0 CD RW DVD installed Maximum HDD capacity 3 5 inch SAS 600GB 2 x 300GB hot swap 3 5 inch SAS x1X x1Y L2X L2Y x3X x4Y x3X x4Y x5X x5Y x7X x7Y x9X x9Y 2 5 inch SAS 587 6GB 4 x 146 8GB hot swap 2...

Page 15: ...Predictive Failure Analysis support Processors memory voltage regulator modules VRMs HDDs power supplies plus fans when an optional Remote Supervisor Adapter SlimLine II is used Power supply size 670W...

Page 16: ...disk storage Up to 2TB of internal SATA II storage 600GB of internal SAS storage 3 5 inch or 587 2GB of internal SAS storage 2 5 inch High performance external expansion Six 480Mbps USB 2 0 ports two...

Page 17: ...hot spare memory or Memory mirroring Slotless hardware based RAID 1 disk mirroring and RAID 10 striped mirrored arrays standard optional slotless RAID 1E 5 6 highly available arrays Hot swap SAS hard...

Page 18: ...in all countries in which IBM operates IBM PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A...

Reviews: