LED
Problem
Action
SP
The
service
processor
has
failed.
Remove
ac
power
from
the
server;
then,
reconnect
the
server
to
ac
power
and
restart
the
server.
Update
the
firmware
on
the
BMC.
If
a
Remote
Supervisor
Adapter
II
SlimLine
is
installed,
update
the
firmware;
if
the
problem
remains,
replace
the
adapter.
If
the
problem
remains,
replace
the
system
board
(trained
service
technician
only).
DASD
A
hard
disk
drive
error
has
occurred.
Check
the
LEDs
on
the
hard
disk
drives
and
replace
the
indicated
drive.
If
the
problem
remains,
replace
the
hard
disk
drive
backplane
(trained
service
technician
only).
BRD
An
error
has
occurred
on
the
system
board.
v
Check
the
LEDs
on
the
system
board
to
identify
the
component
that
is
causing
the
error.
v
Check
the
system
error
log
for
information
about
the
error.
FAN
A
fan
has
failed,
is
operating
too
slowly,
or
has
been
removed.
The
TEMP
LED
might
also
be
lit.
Replace
the
failing
fan,
which
is
indicated
by
a
lit
LED
on
the
fan
body.
TEMP
The
system
temperature
has
exceeded
a
threshold
level.
A
failing
fan
can
cause
the
TEMP
LED
to
be
lit.
v
Determine
whether
a
fan
has
failed.
If
it
has,
replace
it.
v
Make
sure
that
the
room
temperature
is
not
too
high.
See
for
temperature
information.
v
Make
sure
that
the
air
vents
are
not
blocked.
RAID
A
RAID
controller
error
has
occurred.
Check
the
system
error
log
for
information
about
the
error.
PCI
An
error
has
occurred
on
a
PCI
bus
or
on
the
system
board.
An
additional
LED
will
be
lit
next
to
a
failing
PCI
slot.
v
Check
the
LEDs
on
the
PCI
slots
to
identify
the
component
that
is
causing
the
error.
v
Check
the
system
error
log
for
information
about
the
error.
v
If
you
cannot
isolate
the
failing
adapter
through
the
LEDs
and
the
information
in
the
system
error
log,
remove
one
adapter
at
a
time
from
the
failing
PCI
bus,
and
restart
the
server
after
each
adapter
is
removed.
If
the
problem
remains,
replace
the
following
components,
in
the
order
shown,
restarting
the
server
each
time:
v
PCI
riser
card
v
(Trained
service
technician
only)
System
board
Power-supply
LEDs
The
following
minimum
configuration
is
required
for
the
DC
LED
on
the
power
supply
to
be
lit:
v
Power
supply
v
Power
backplane
v
Power
cord
The
following
minimum
configuration
is
required
for
the
server
to
start:
v
One
microprocessor
v
Two
512
MB
DIMMs
on
the
system
board
v
One
power
supply
v
Power
backplane
v
Power
cord
v
RAID
controller
Chapter
3.
Diagnostics
53
Summary of Contents for 7985
Page 1: ...IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Page 18: ...xvi IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Page 36: ...18 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Page 110: ...92 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Page 112: ...View 1...
Page 159: ...Battery Chapter 5 Removing and replacing server components 141...
Page 202: ...184 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Page 212: ...194 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide...
Page 217: ......