B-28
8237 Hub Installation and Planning Guide
ACCESS read-only
STATUS mandatory
DESCRIPTION "ID of a hub."
::= { securityPortEntry 1 }
securityPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Port number in a hub."
::= { securityPortEntry 2 }
securityAuthorizedAddr OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION "Authorized source MAC address assigned to the
port."
::= { securityPortEntry 3 }
securityAutoLearnAction OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2),
learned(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "Setting this object to inactive(1) disables the
auto-learn function for the authorized physical
address of this port. Once this object is set
to active(2), the agent will set the authorized
address to 0 first and then start the auto-
learn process and the hub will begin to read
the source address of the first incoming error-
free frame. The source address obtained will
become the authorized address and the object
securityAuthorizedAddr will be changed
accordingly. When the authorized address has
been learned successfully, the status of this
port will be reflected as learned(3).
Otherwise the status will remain as active(2).
Setting to the last value, learned(3), is not
acceptable; ’snmpBadValue’ will be returned."
::= { securityPortEntry 4 }
securityIntrusionAction OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
notify(2),
notify-and-disable(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The object sets the action mode when the
source address of the port is different from
the securityAuthorizedAddr.
When set to inactive(1), disables the
intrusion protection of this port.
When set to notify(2), enables the intrusion
protection of the port. If the port receives a
frame with a source address different from the
securityAuthiruzedAddr, the agent sends a trap
message to the trap managers.
Summary of Contents for 8237
Page 1: ......
Page 2: ......
Page 7: ...vi 8237 Hub Installation and Planning Guide...
Page 15: ...xiv 8237 Hub Installation and Planning Guide...
Page 41: ...2 8 8237 Hub Installation and Planning Guide...
Page 91: ...3 50 8237 Hub Installation and Planning Guide...
Page 109: ...4 18 8237 Hub Installation and Planning Guide Figure 4 20 8237 Field Replaceable Parts...
Page 113: ...4 22 8237 Hub Installation and Planning Guide...
Page 117: ...A 4 8237 Hub Installation and Planning Guide...
Page 147: ...B 30 8237 Hub Installation and Planning Guide...
Page 166: ...Part Number 85H8847 Printed in Taiwan 85H8847 GA27 4186 00...