Note:
The system-error log is available on the xSeries 206 server only when
the server contains an optional Remote Supervisor Adapter II.
Complete the following steps to perform the checkout procedure:
001
IS THE SERVER PART OF A CLUSTER?
YES.
Schedule maintenance for the server. Shut down all servers related to
the cluster. Run the storage test.
NO.
Go to step
002
.
002
IF THE SERVER IS NOT PART OF A CLUSTER:
If the operating system is running, complete the following steps:
1. Check the system board for LEDs (see “Diagnostic LEDs” on page 19).
2. If the xSeries 206 server has an optional Remote Supervisor Adapter II,
check the service processor system-error logs:
a. If the system-error log indicates a damaged field replaceable unit
(FRU), replace the FRU, and run the diagnostic programs to confirm
that the problem has been solved.
b. If the system-error log does not indicate a damaged FRU, see “Error
symptoms” on page 86 and “Undetermined problems” on page 97.
If the operating system is not running, complete the following steps:
1. Check the system board for LEDs (see “Diagnostic LEDs” on page 19).
2. If the xSeries 206 server has an optional Remote Supervisor Adapter II,
check the service processor system-error logs:
a. If the system-error log indicates a damaged field replaceable unit
(FRU), replace the FRU, and run the diagnostic programs to confirm
that the problem has been solved.
b. If the error log does not indicate a damaged FRU, check the
operating-system event logs; if these logs do not specify a particular
error, go to step 3.
3. Turn off the server and all external devices.
4. Check all cables and power cords.
5. Set all display controls to the middle position.
6. Turn on all external devices.
7. Turn on the server.
8. Watch the screen and the serial port for POST errors, and record any
POST error messages that are displayed on the screen. If an error is
displayed, look up the first error (see “POST error codes” on page 80).
9. Run the diagnostic programs (see “Starting the diagnostic programs and
viewing the test log” on page 17).
003
DID THE DIAGNOSTIC PROGRAMS START ?
NO.
Find the failure symptom in “Error symptoms” on page 86.
YES.
Run the diagnostic programs (see “Starting the diagnostic programs
and viewing the test log” on page 17).
If you receive an error, see Chapter 7, “Symptom-to-FRU index,” on page
77.
If the diagnostics were completed successfully and you still suspect a
problem, see “Undetermined problems” on page 97.
If the server does not turn on, see “Error symptoms” on page 86.
14
xSeries 206 Type 8482 and 8487: Hardware Maintenance Manual and Troubleshooting Guide
Summary of Contents for 84875MU
Page 1: ...xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 2: ......
Page 3: ...xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 6: ...iv xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 10: ...viii xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 22: ...12 xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 68: ...58 xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 86: ...76 xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 127: ...Appendix B Related service information 117...
Page 128: ...118 xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 129: ...Appendix B Related service information 119...
Page 130: ...120 xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 131: ...Appendix B Related service information 121...
Page 132: ...122 xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 133: ...Appendix B Related service information 123...
Page 143: ...Appendix B Related service information 133...
Page 144: ...134 xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 145: ...Appendix B Related service information 135...
Page 146: ...136 xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 150: ...140 xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 159: ......
Page 160: ...Part Number 49Y0092 Printed in USA 1P P N 49Y0092...