If
the
amber
hard
disk
drive
status
LED
for
a
drive
is
lit
continuously,
that
drive
is
faulty
and
needs
to
be
replaced.
If
the
green
hard
disk
drive
activity
LED
is
flashing,
the
drive
is
being
accessed.
Note:
If
your
server
is
configured
for
RAID
operation
using
the
integrated
SCSI
controller
with
RAID
capabilities
or
an
optional
ServeRAID
controller,
you
might
need
to
reconfigure
your
disk
arrays
after
installing
hard
disk
drives.
See
the
ServeRAID
documentation
on
the
IBM
ServeRAID
Support
CD
for
additional
information
about
RAID
operation
and
complete
instructions
for
using
ServeRAID
Manager.
6.
If
you
are
installing
additional
hot-swap
hard
disk
drives,
do
so
now;
otherwise,
continue
with
step
7.
7.
Make
sure
the
side
cover
is
unlocked;
then
insert
the
hot-swap
lock
bar
into
the
slots
on
the
bezel
and
rotate
it
to
the
locked
position.
8.
Hold
the
hot-swap
lock
bar
in
the
closed
position,
lock
the
side
cover
key
lock,
and
close
the
server
door.
SCSI
IDs
for
hot-swap
hard
disk
drives
The
hot-swap-drive
backplane
controls
the
SCSI
IDs
for
the
internal
hot-swap
drive
bays.
The
SCSI
ID
for
each
hot-swap
hard
disk
drive
is
printed
on
the
hot-swap
lock
bar.
Table
5
lists
the
SCSI
IDs
for
the
hard
disk
drives
and
backplane
that
are
connected
to
one
channel
in
hot-swap
hard
disk
drive
models.
In
the
typical
configuration,
the
standard
hard
disk
drives
and
backplane
are
connected
to
channel
A.
Table
5.
SCSI
IDs
for
standard
hot-swap
hard
disk
drives
and
backplane
Device
SCSI
ID
Drive
bay
9
0
Drive
bay
8
1
Drive
bay
7
2
Drive
bay
6
3
Drive
bay
5
4
Drive
bay
4
5
Backplane
8
Installing
non-hot-swap
hard
disk
drives
Bays
4,
5,
6,
and
7
are
in
the
drive
cage.
The
drive
cage
is
behind
the
front
of
the
adapter-support
bracket.
Drives
are
installed
starting
at
the
bottom
in
bay
7.
Additional
drives
are
then
installed
in
bays
6,
5,
and
4.
Notes:
1.
You
can
install
up
to
four
non-hot-swap
hard
disk
drives
in
your
server.
The
additional
space
in
the
drive
cage
above
bay
4
is
not
designed
to
accommodate
any
additional
drives.
2.
When
installing
non-hot-swap
hard
disk
drives,
you
might
find
it
easier
to
lay
the
server
on
its
side.
Complete
the
following
steps
to
install
a
drive
in
bay
4,
5,
6,
or
7:
1.
Review
the
safety
information
beginning
on
page
129
and
“Installation
guidelines”
on
page
33.
2.
Turn
off
the
server
and
all
attached
devices.
48
IBM
xSeries
225
Types
8649:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Summary of Contents for 8649 - Eserver xSeries 225
Page 1: ...IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 2: ......
Page 3: ...IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 6: ...iv IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 16: ...6 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 28: ...18 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 42: ...32 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 84: ...74 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 130: ...120 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 151: ...Appendix B Related service information 141 ...
Page 152: ...142 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 153: ...Appendix B Related service information 143 ...
Page 154: ...144 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 155: ...Appendix B Related service information 145 ...
Page 156: ...146 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 157: ...Appendix B Related service information 147 ...
Page 158: ...148 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 171: ...Appendix B Related service information 161 ...
Page 172: ...162 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 173: ...Appendix B Related service information 163 ...
Page 174: ...164 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 175: ...Appendix B Related service information 165 ...
Page 176: ...166 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 177: ...Appendix B Related service information 167 ...
Page 182: ...172 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 188: ...178 IBM xSeries 225 Types 8649 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 193: ......