Notes
1. The Multiple Controller mode has two
settings: Erase and Shrink. When this
parameter is set to Erase, redundant copies
of the ServeRAID BIOS are erased. When
this parameter is set to Shrink, the extra
copies of the ServeRAID BIOS are removed
from memory, but stored for future use.
When you have multiple ServeRAID
adapters and controllers installed, you need
only one active copy of ServeRAID BIOS.
However, to ensure that you will have a
copy of the ServeRAID BIOS available if the
active copy becomes defective or
unavailable, leave the Multiple Controller
parameter set to Shrink.
2. Only one adapter or controller in the system
can support the INT13 extensions.
View Controller and PCI Information shows the
ServeRAID adapter or controller hardware and PCI
register information.
Exit lets you exit the Mini-Configuration program.
Setting the bootable CD-ROM feature:
When you attach a CD-ROM drive to the ServeRAID
adapter or controller and set the Bootable CD-ROM feature
to Yes, the ServeRAID adapter or controller will attempt to
start a CD that has a bootable startup partition, if no other
adapter or controller in the system is currently using INT13
extensions. Only one adapter or controller in the system
can support the INT13 extensions.
To enable the Bootable CD-ROM feature:
1. Select Advanced Functions from the Main Menu of
the Mini-Configuration program.
2. Select Configure BIOS Settings from the Advanced
Functions menu.
3. Use the Up Arrow (
↑
) and Down Arrow (
↓
) keys to
highlight BIOS Support for Bootable CD-ROM; then,
press Enter to change No to Yes.
Note
This also changes No to Yes next to Display
Boot CD-ROM Menu and BIOS Support for
INT13 Extensions.
4. Ensure that the screen has Yes next to BIOS
Support for Reading Partition Tables. If not, use
the Up Arrow (
↑
) and Down Arrow (
↓
) keys to
highlight BIOS Support for Reading Partition
Tables; then, press Enter to change No to Yes.
Netfinity 5500 M20 - Type 8662
97
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...