device states” on page 112 for more
information.)
UNBLOCK
Use the UNBLOCK command to gain access
to a blocked logical drive. RAID level-0
logical drives become blocked if they are in
an array that contains RAID level-1 or level-5
logical drives and the array is being rebuilt.
Because the RAID level-0 logical drives
cannot be rebuilt, the data stored on the
RAID level-0 logical drives is damaged and
should not be accessed. After you issue the
UNBLOCK command, you must re-create or
restore the data previously stored on the
RAID level-0 logical drives.
Supported operating systems: Windows NT,
OS/2, NetWare, OpenServer, UnixWare, and
DOS
Command:
IPSSEND UNBLOCK
Controller DriveNum
Replace:
Controller with the ServeRAID controller
number (1 to 8)
DriveNum with the logical drive number
(0 to 7)
ServeRAID problem-isolation and debug
commands:
The IPSSEND problem-isolation and debug commands
include the following:
CERTIFY
Use the CERTIFY command to verify the
media of a hard disk drive. If the program
finds a media error, it reassigns the sectors.
A summary of reassignments and PFA errors
appears upon completion of the verification.
Supported operating system: DOS
Command:
IPSSEND CERTIFY
Controller Channel SID
Replace:
Controller with the ServeRAID controller
number (1 to 8)
Channel with the channel number for the
device (1, 2, or 3)
SID with the SCSI ID for the device (0 to
15)
ERASEEVENT Use the ERASEEVENT command to clear
all logged entries in the designated event log.
See GETEVENT help for information about
the contents of the Device Event Log and the
Adapter Soft and Hard Event Logs.
124
Netfinity Server HMM
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...