If you start this program without any command-line
parameters, the IPSMON program will log the messages to
the IPSMON.LOG file, and the messages will not appear
on the monitor.
The valid parameters for IPSMON are:
-f:
filename
Use the -f parameter to specify the name of the file in
which to record messages. The default file name is
IPSMON.LOG.
-s
Use the -s parameter to display messages on the
standard output (usually the monitor).
-?
Use the -? parameter to obtain a current list of valid
parameters.
After you start the IPSMON program, the program will
continuously poll the ServeRAID adapters and controllers
until you take one of the following actions:
If you are using Windows NT or OS/2, press Ctrl
+
C.
If you are using NetWare, type:
unload ipsmon
at the
system console.
If you are using OpenServer or UnixWare, press the
Del key to cancel the program.
During operation, the program will log various messages.
Each message will contain an alert code and a location
specifier.
The alert code begins with the message type and
number. For example, INF, WRN, or CRT, followed
by the message number.
After the alert code comes the location specifier:
A specifies the adapter or controller number
SID specifies the SCSI ID (if required)
C specifies the channel number (if required)
For example, a message of CRTxxx:A2C3SID04 signifies
that a Critical condition (CRTxxx) was found on Adapter 2
(A2), Channel 3 (C3), SCSI ID 4 (SID04).
The IPSMON program can log the following messages,
based on the required condition.
Information Messages:
<Date and Time> INF000:A1C-SID
-- no errors detected
<Date and Time> INF001:A1C-SID
-- rebuild started
<Date and Time> INF002:A1C-SID
-- rebuild completed
<Date and Time> INF003:A1C-SID
-- synchronization started
<Date and Time> INF004:A1C-SID
Netfinity 5500 M20 - Type 8662
129
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...