Notes
1. The
a represents the drive assignment for
the diskette drive that contains the
ServeRAID diskette.
2. If you install these files on a logical drive
that has its write policy set to the write-back
mode, wait at least 10 seconds after being
prompted to press Ctrl
+
Alt
+
Del before you
actually press the keys. Waiting 10 seconds
or longer gives the ServeRAID adapter or
controller the time needed to flush all
dirty-cache pages out to the hard disk.
4. Press Enter. Then, type:
ddinstal
5. Press Enter.
The OS/2 Device Driver Installation window will
appear and prompt you for the source and destination
drives. The source directory shows where to insert
the
IBM ServeRAID Device Driver Diskette. The
destination directory shows where the program will
copy the device driver files.
6. Select Install.
The program copies the following ServeRAID
device driver statement to the CONFIG.SYS file:
BASEDEV=IPSRAID.ADD
The program copies the following ServeRAID
device driver and program files to the OS/2
subdirectory on the hard disk: IPSRAID.ADD,
IPSADM.EXE, and IPSRADM.EXE
The program copies the following ServeRAID
Help file to the \OS2\HELP directory:
IPSRADM.HLP
7. Edit the CONFIG.SYS file and verify that there is only
one copy of the line BASEDEV=IPSRAID.ADD.
Notes
1. If you have more than one ServeRAID or
SCSI adapter in the system, make sure that
the BASEDEV statement for the adapter
controlling the startup (boot) device appears
before the BASEDEV statements for other
ServeRAID or SCSI adapters in the
CONFIG.SYS file.
2. After you install any service packs, check
the path for the IPSRAID.ADD device driver
and verify that the correct device driver is
installed.
8. Restart the server.
142
Netfinity Server HMM
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...