Starting the Administration and Monitoring
Program:
To start the ServeRAID Administration and
Monitoring Program for OS/2:
1. Go to the OS/2 subdirectory on the hard disk drive;
then, type:
ipsradm
/lf=d:\path\logfile
Notes
1. Make sure that the path you type exists.
The program will not create a path.
2.
Logfile is where the program will log
messages.
3. If you omit the
/lf parameter, the program
will create the
IPSRADM.LOG default file in
the OS2 subdirectory to log the program
messages.
2. Press Enter.
3. Use the following steps if you want to define
IPSRADM to OS/2:
a. Open the Templates Folder on the OS/2
Desktop.
b. Drag a program template onto the Desktop. A
Program Settings window will appear.
c. At the Program page in the Path and File Name
field, type:
c:\os2\ipsradm.exe
d. In the Parameters field, type:
/lf=d:\path\logfile
e. At the General Tab in the Title field, type:
ServeRAID
Installing ServerRAID device drivers for
OpenServer:
To use the ServeRAID Administration and Monitoring
Program with SCO, you must first install the WIN32-Based
version of the Administration and Monitoring Program on a
Windows NT or Windows 95 client. Then, attach the
Windows NT or Windows 95 client to the same network as
the OpenServer systems that contain the ServeRAID
adapters or controllers. Finally, you must install the
ServeRAID device driver and background-server
component for OpenServer.
The background-server component for OpenServer installs
automatically when you use the instructions in this chapter
to install the ServeRAID OpenServer device driver. This
component enables the OpenServer system to act as the
TCP/IP interface for the remote WIN32-Based Program.
(See “ServeRAID programs for Windows NT and Windows
95” on page 131 for more information.)
Netfinity 5500 M20 - Type 8662
143
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...