f. Record the slot number for the ServeRAID
adapter or controller; then, press Esc three times
to return to the controller selection screen.
g. Repeat step 3c on page 147 through step 3f
until you record the slot number for each
ServeRAID adapter or controller that appears on
the selection screen.
4. Turn off the system; then, remove all ServeRAID
adapters and controllers except the first one on the
list.
Note
If one of the ServeRAID controllers that you need
to remove is on the system board, you must do
one of the following:
If the CD-ROM drive that you are using to
install the operating system is attached to
the integrated ServeRAID controller,
disconnect or remove all disk drives
attached to the integrated controller.
If only disk drives are attached to the
integrated controller, disconnect the SCSI
cable from the ServeRAID connector on the
system board. See the label inside the
server cover for the location of the
ServeRAID connector.
5. Remove all other non-ServeRAID IDE and SCSI
disk-storage adapters and controllers.
Note
If one of the disk-storage controllers that you
need to remove is on the system board, you
must do one of the following:
If the CD-ROM drive that you are using to
install the operating system is attached to
the integrated disk-storage controller,
disconnect or remove all disk drives
attached to the integrated controller.
If only disk drives are attached to the
integrated controller, disconnect the cable
for the integrated controller from the IDE or
SCSI connector on the system board. See
the label inside the server cover for the
location of the IDE or SCSI controller
connector.
6. Follow the instructions in “Installing the files while
installing UnixWare” on page 150; then, return here
and continue with
step 7.
7. Power down the system.
148
Netfinity Server HMM
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...