Installing IPSSEND and IPSMON for
UnixWare:
To install these programs for UnixWare 7.0:
1. Insert the
IBM ServeRAID Command Line Programs
Diskette into the diskette drive.
2. Copy the program files from the
IBM ServeRAID
Command Line Programs Diskette by typing the
following:
doscp –r a:/unixware/ipssend /usr/bin/ipssend
3. Press Enter; then, type:
doscp –r a:/unixware/ipsmon /usr/bin/ipsmon
4. Press Enter; then, change the access permissions by
typing the following:
chmod 7ðð /usr/bin/ipssend
5. Press Enter; then, type:
chmod 7ðð /usr/bin/ipsmon
6. Press Enter; then, refer to “Starting the ServeRAID
Administration and Monitoring Program” on page 98
for information to start and use the IPSSEND and
IPSMON programs.
Installing IPSSEND for DOS:
To install IPSSEND for DOS:
1. Create a startable diskette. To do this, insert a blank
diskette in diskette drive A; then, type:
format a: /s
2. Press Enter.
3. Copy the ASPI device driver from the DOS directory
on the
IBM ServeRAID Device Driver Diskette to the
startable diskette.
4. Copy the IPSSEND.EXE file from the DOS directory
on the
IBM ServeRAID Command Line Programs
Diskette to the startable diskette.
5. Leaving the startable diskette in the diskette drive,
restart the system; then, refer to “Starting the
ServeRAID Administration and Monitoring Program”
on page 98 for information to start and use the
IPSSEND and IPSMON programs.
Rebuilding a defunct drive
When a hard disk drive goes defunct (DDD), a Rebuild
operation is required to reconstruct the data for the device
in its respective disk array. The ServeRAID adapters and
controllers can reconstruct RAID level-1 and RAID level-5
logical drives, but they cannot reconstruct data stored in
RAID level-0 logical drives.
To prevent data integrity problems, the ServeRAID
adapters and controllers set the RAID level-0 logical drives
Netfinity 5500 M20 - Type 8662
157
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...