need to install it again if you ever remove the
microprocessor.
5. Install the microprocessor:
a. Touch the static-protective package containing
the new microprocessor to any unpainted metal
surface on the server; then, remove the
microprocessor from the package.
b. Hold the microprocessor
.4/
by the open latches
.3/
, and center the microprocessor over the
microprocessor connector
.9/
.
Attention
Make sure the microprocessor is oriented
and aligned correctly before you try to close
the latches.
c. Carefully close the latches
.3/
to seat the
microprocessor in the connector.
6. Install the voltage regulator modules (VRMs)
.12/
included in the microprocessor kit:
a. Remove fan assembly 4 to allow access to the
VRM connectors. See “Hot-swap fan assembly
replacement” on page 202 for instructions on
removing fan assembly 4.
b. Determine the connectors where the VRMs are
to be installed. See Table 13 on page 240.
The microprocessor upgrade kit comes with two
VRMs. You might need to install only one,
depending upon the number of microprocessors
in the server.
c. Center the VRM
.12/
over the connector
.11/
.
Make sure that the VRM is oriented and aligned
correctly; then, press the VRM into the
connector.
d. Repeat the preceding step for the second VRM,
if needed. If you need to install only one VRM,
store the remaining VRM in a safe place to use
as a replacement, if you ever need one.
Note
If you remove the microprocessor at some
time in the future, remember to install the
terminator card in the appropriate
microprocessor connector and to remove the
VRMs for that microprocessor.
e. Install fan assembly 4. See “Hot-swap fan
assembly replacement” on page 202 for
instructions on installing fan assembly 4.
7. Install the processor support tray cover
.1/
and turn
the two quarter-turn fasteners
.2/
one quarter turn to
secure the cover.
244
Netfinity Server HMM
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...