Beep/Symptom
FRU/Action
3-3-1
(Memory size mismatch
occurred, see“Memory
settings” on page 30 )
1. DIMM
2. Processor Board
3. Battery
3-3-2
(Critical SMBUS error
occurred)
1. Disconnect the
server power cord
from outlet, wait 30
seconds and retry.
2. Processor Board
3. Memory DIMMs
3-3-3
(No operational memory in
system)
1. Install or reseat the
memory modules,
then do a 3 boot
reset (see
“Configuration/Setup
Utility program” on
page 21)
2. DIMMs
3. Memory Board
4. Processor Board
5. System Board
Two Short Beeps
(Information only, the
configuration has changed)
1. Run Diagnostics
2. Run
Configuration/Setup
Three Short Beeps
1. DIMM
2. Processor Board
3. System Board
One Continuous Beep
1. Processor
2. Optional Processor
(if installed)
3. Processor Board
4. System Board
Repeating Short Beeps
1. Keyboard
2. System Board
One Long and One Short
Beep
1. Video adapter
(if present)
2. System Board
3.
One Long and Two Short
Beeps
1. Video adapter
(if present)
2. System Board
Two Long and Two Short
Beeps
1. Video adapter
No beep symptoms
No Beep Symptom
FRU/Action
No beep and the system
operates correctly.
1. Check speaker
cables
2. Speaker
3. System Board
288
Netfinity Server HMM
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...