Error Code/Symptom
FRU/Action
201-XXX-004
(Failed Memory test,
see“Memory settings” on
page 30 )
1. DIMM Location J4
201-XXX-005
(Failed Memory test,
see“Memory settings” on
page 30 )
1. DIMM Location J5
201-XXX-006
(Failed Memory test,
see“Memory settings” on
page 30 )
1. DIMM Location J6
201-XXX-007
(Failed Memory test,
see“Memory settings” on
page 30 )
1. DIMM Location J7
201-XXX-008
(Failed Memory test,
see“Memory settings” on
page 30 )
1. DIMM Location J8
201-XXX-999
(Multiple DIMM failure, see
error text.)
1. See error text for
failing DIMMs
202-XXX-001
(Failed System Cache test)
1. VRM 2 or VRM 1
2. Microprocessor CPU 1
202-XXX-002
(Failed System Cache test)
1. VRM 2 or VRM 3
2. Microprocessor CPU 2
202-XXX-003
(Failed System Cache test)
1. VRM 5 or VRM 4
2. Microprocessor CPU 3
202-XXX-004
(Failed System Cache test)
1. VRM 5 or VRM 6
2. Microprocessor CPU 4
206-XXX-000
(Failed Diskette Drive test)
1. Cable
2. Diskette Drive
3. System Board
215-XXX-000
(Failed IDE CD-ROM test)
1. CD-ROM Drive
Cables
2. CD-ROM Drive
3. System Board
217-XXX-000
(Failed BIOS Fixed Disk
test)
Note
If RAID is configured,
the fixed disk number
refers to the RAID
logical array.
1. Fixed Disk 1
Netfinity 5500 M20 - Type 8662
297
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...