POST error codes
In the following error codes,
X can be any number or letter.
Error Code/Symptom
FRU/Action
062
(Three consecutive boot
failures using the default
configuration.)
1. Run
Configuration/Setup
2. Battery
3. System Board
101, 102
(System and processor
error)
1. System Board
2. Processor Board
106
(System and processor
error)
1. System Board
2. Processor Board
111
(Channel check error)
1. Failing ISA Adapter
2. Memory DIMM
3. System Board
114
(Adapter read-only memory
error)
1. Failing Adapter
2. Run Diagnostics
129
(Internal Cache error)
1. Processor
2. Optional Processor
(if installed)
3. Processor Board
151
(Real time clock error)
1. Run Diagnostics
2. Battery
3. System Board
161
(Real time clock battery
error)
1. Run
Configuration/Setup
2. Battery
3. System Board
162
(Device Configuration Error)
Important
Be sure to load the
default settings and
any additional desired
settings; then, save
the configuration.
1. Run
Configuration/Setup
2. Battery
3. Failing Device
4. System Board
163
(Real-Time Clock error)
1. Run
Configuration/Setup
2. Battery
3. System Board
164
(Memory configuration
changed, see “Memory
settings” on page 30)
1. Run
Configuration/Setup
2. DIMM
3. Processor Board
175
(Hardware error)
1. System Board
2. Processor Board
176
(Computer cover or cable
cover was removed without
a key being used)
1. Run
Configuration/Setup
2. System Board
304
Netfinity Server HMM
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......