ServeRAID controller error
codes/messages
The error codes/messages are displayed on the screen in
a line of text immediately after the controller BIOS version.
If POST detects changes in the controller configuration or
detects an controller hardware problem, messages appear
on the screen. Refer to “ServeRAID POST error
procedures” on page 314 and correct the problem.
If there is no POST Error or Configuration Error message,
the BIOS screen resembles the sample shown below.
Please note that your version may be different from the
one shown.
à
ð
__________________________________
IBM ServeRAID BIOS
Copyright IBM Corp. 1995,1998
Ver: 3.ðð.12
ð8/14/1998
__________________________________
«« Press Ctrl+I to access the Mini-Configuration Program. »»
Initializing ServeRAID Controller 1 in Slot 1.
Power-on self-test can take up to 59 Second(s) -- test Passed.
Drive configuration can take up to 6 Minute(s) ð
Second(s) -- test Passed.
ServeRAID Firmware Version:2.82.ðð
No logical drives found; none are installed.
Non-Disk SCSI Devices Found: CD-ROM ð, Tape ð, Removable-media ð, Other 1.
BIOS not loaded no devices found - Installation stopped.
á
ñ
If there is a POST Error message, the BIOS screen
resembles the sample shown below. Refer to “ServeRAID
POST error codes” on page 314 and correct the problem.
The characters
XXXX indicate the POST (ISPR) error.
à
ð
__________________________________
IBM ServeRAID BIOS
Copyright IBM Corp. 1995,1998
Ver: 3.ðð.12
ð8/14/1998
__________________________________
«« Press Ctrl+I to access the Mini-Configuration Program. »»
Initializing ServeRAID Controller 1 in Slot 1.
Power-on self-test can take up to 59 Second(s) -- test Failed.
Controller is not responding properly - Run Diagnostics.
Error Code: XXXX-YY
BIOS not loaded no devices found - Installation stopped.
á
ñ
The BIOS screen below shows Configuration Status and/or
Error information. Refer to “ServeRAID Startup Messages”
on page 318.
312
Netfinity Server HMM
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...