à
ð
__________________________________
IBM ServeRAID BIOS
Copyright IBM Corp. 1995,1998
Ver: 3.ðð.12
ð8/14/1998
__________________________________
«« Press Ctrl+I to access the Mini-Configuration Program. »»
Initializing ServeRAID Controller 1 in Slot 1.
Power-on self-test can take up to 59 Second(s) -- test Passed.
Drive configuration-can take up to 6 Minute(s) ð
Second(s) -- test Failed.
Controller POST and Config Error Codes: ISPR = EF1ð BCS = ð9 ECS = 2ð.
Following drives not responding(old state: new state: ch SID)
(RDY:EMP: 2:ð)
The system has a configuration error due to above condition(s).
Press: F4
- Retry the command
F5
- Update Controller configuration to exclude NON-RESPONDING drives
Warning:NON-RESPONDING drives will be set to DDD, DHS, or EMP state
F1ð - Exit without change
á
ñ
Note
Do not replace a system board containing an
imbedded ServeRAID controller for ServeRAID
problems unless replacing the controller is listed in the
Symptom-to-FRU Index.
Netfinity 5500 M20 - Type 8662