Note
Refer to the HMM (Hardware Maintenance
Manual) specific to the system comprising
the SCSI channel for termination details.
c. Disconnect one drive at a time attached to
channel identified in step 1a and reboot each
time to determine which drive is causing the
problem.
d. Replace SCSI Cable attached to channel
identified in step 1a.
e. Replace Backplane attached to channel
identified in step 1a.
2. If original ISPR code is still present after
disconnecting all SCSI cables and rebooting, perform
the following actions until the error is no longer
present:
Reseat the controller
Replace the controller
Netfinity 5500 M20 - Type 8662