Bypassing an unknown power-on
password
When a power-on password is set, POST does not
complete until you enter the password. If you forget the
power-on password, you can regain access to the server
through either of the following methods:
Enter the administrator password at the power-on
prompt, if an administrator password has been set.
(If necessary, see “Using the Administrator Password
menu” on page 28 for details.) Start the
Configuration/Setup Utility program and change the
power-on password. See “Using the power-on
password menu” on page 26.
Change the position of the jumper on J24 as
described in Table 18 on page 280 to bypass the
power-on password check. You can then start the
Configuration/Setup Utility program and change the
power-on password. See “Using the power-on
password menu” on page 26.
Ethernet subsystem error messages
Notes
1. The following error messages may be displayed if
"Network" is selected in the startup sequence of
the configuration program.
2. The following error messages are available only
with the integrated Ethernet subsystem. These
error messages are not available when RPL
(remote program load) or DHCP (dynamic host
configuration protocol) is used through optional
network adapters.
RPL-related error messages:
If a failure condition occurs after the Ethernet controller is
initialized, an error message appears on the screen.
The two most common error messages are:
RPL-ROM-ERR:
1ð5
The integrated Ethernet failed the loopback test.
RPL-ROM-ERR:
1ð7
Media test failed; check the cable.
Error 105 indicates that a power-on diagnostic test
performed by the Ethernet module did not execute
correctly.
Error 107 indicates that the cable from the LAN is not
securely connected to the Ethernet port on the computer.
Check the cable to ensure that it is properly connected.
The following list contains other error codes that might
occur, followed by a description of the error code.
Netfinity 5500 M20 - Type 8662
45
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...