Descriptions of the choices available from the Advanced
Functions menu are as follows:
Attention
The following choices might result in loss of data
due to changes in the configuration.
Initialize Configuration resets the ServeRAID
controller settings to their factory defaults and sets all
functional hard disk drives to the RDY state.
Import Configuration from Drive(s) reads the most
common configuration information from the drives in
the server and copies it to the controller’s NVRAM
and to the controller’s EEPROM module.
Boot CD-ROM and INT13 Extensions is used to
configure the BootCd feature. When BootCd is
enabled, the ServeRAID controller attempts to start
(boot) from a CD, if the CD-ROM drive contains a
startable (boot-enabled) CD, and no other controller is
currently using INT13 extensions.
Attention
Only one controller can support INT13
extensions.
Adapter and PCI Information displays the
ServeRAID controller hardware and PCI register
information, as shown in the following example
screen.
Press any key to continue.
IBM ServeRAID Adapter Disk Array Mini-Configuration Utility Ver. X.XX
CB80h
9A00h
1
0009h
F400h
FDFFE000h
00h
0Eh
0009E814h
0009E82Ch
0009E818h
0009E814h
4800h
01K8562
Code Seg.(Cs):
Data Seg.(Ds):
Adapter No:
Intr No:
I/O Adr:
Mem Adr:
Bus No:
Device No:
StatusQ Start:
StatusQ End:
StatusQ Head:
Status Tail:
OS/2 Table:
Part Number:
Adapter Information
PCI Reg Information
002Eh 1014h
0200h 0107h
010000h 04h
00h 00h 40h 08h
0000F401h
FDFFE000h
00000000h
00000000h
00000000h
00000000h
00000000h
00000000h
00000000h
00000000h
00000000h
00h 00h 00h 00h
Dev, Ven Id (00h):
Status, Cmd(04h):
Class, Rev Id(08h):
Bist,Hdr,Lat,Cach (0Ch):
Base Adr Reg0(10h):
Base Adr Reg1(14h):
Base Adr Reg2(18h):
Base Adr Reg3(1Ch):
Base Adr Reg4(20h):
Base Adr Reg5(24h):
Reserved(28h):
Reserved(2Ch):
Exp ROM Adr(30h):
Reserved (34h):
Reserved(38h):
MaxLat,MinG,IntP,Intl(3Ch):
Setting the BootCd feature:
When you select Boot CD-ROM and INT13 Extensions, a
screen similar to the following appears.
64
Netfinity Server HMM
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...