Parity Space in MB shows the amount of space in
the logical drive allocated for parity storage.
Date Created shows the date that you created the
logical drive.
Write-Cache Mode shows the current setting, write
through or write back, for the logical drive.
Battery Backup Write Cache shows the current
setting, Enabled or Disabled, for the battery backup
cache device. When the battery backup cache device
is installed, write cache is set to the write-back mode.
Merge-Group Number appears if the ServeRAID
controller is part of a cluster. The valid settings in the
Shared state are 1 through 8. Valid settings in the
Non-Shared state are 201 through 215.
Merge-Group State shows the current setting,
Shared or Non-Shared, for this parameter.
Hot-Spare Drive Information Panel
When you select the Hot-Spare Drives icon from the Main
Tree, information about the total number of functional
hot-spare and standby hot-spare drives defined for the
ServeRAID controller appears in the Main Panel on the
right.
When you select a specific hot-spare drive from the Main
Tree, the following information appears in the Main Panel
on the right:
SCSI ID shows the SCSI ID assigned to the drive.
Channel shows the SCSI channel to which the
hot-spare drive is attached.
Drive Type shows the type of physical drive. For a
hot spare, this will always appear as Hard Disk Drive.
Size in MB shows the total capacity of the hard disk
drive in MB.
Drive State shows the drive state. For a hot spare,
this will always appear as Hot Spare.
Vendor shows characters that represent the drive
manufacturer.
Product or Model Number shows characters that
represent the product or model number for the drive.
Serial Number shows the serial number for the drive.
Drive Firmware Level shows the current level of
microcode in use for the drive.
PFA Error indicates the status, Yes or No, for
predictive-failure alerts. Yes indicates that PFA errors
were detected and that you should plan to replace the
device. No indicates that PFA errors were not found.
Physical Drive Information Panel
When you select the Physical Drives icon from the Main
Tree, information about the total number of drives
connected to each channel of the ServeRAID adapter or
controller appears in the Main Panel on the right.
Netfinity 5500 M20 - Type 8662
81
Summary of Contents for 866251Y - Netfinity 5500 M20
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 336: ...32 33 33 34 35 36 37 38 39 40 41 42 43 328 Netfinity Server HMM...
Page 346: ...338 Netfinity Server HMM...
Page 354: ...346 Netfinity Server HMM...
Page 355: ...Related service information 347...
Page 356: ...348 Netfinity Server HMM...
Page 357: ...Related service information 349...
Page 368: ...360 Netfinity Server HMM...
Page 369: ...Related service information 361...
Page 385: ......
Page 386: ...IBM Part Number 09N1015 Printed in U S A S37L 2 2 1...