Replacing a hot-swap fan assembly
The server comes with three hot-swap fan assemblies.
Attention
Replace a fan that has failed within 48 hours to help
ensure proper cooling.
Note
You do not need to turn off the power to the server to
replace a hot-swap fan assembly.
The following illustrations show the replacement of a
hot-swap fan assembly. Refer to these illustrations while
performing the steps in this procedure.
CPU
VRM
MEMOR
Y
HDD
PCI BUS
NMI
SMI
SERVICE PR
OCESSOR
BUS
NON REDUND
ANT
POWER SUPPL
Y
1 2 3
A B
1 2 3
FAN
TEMPERA
TURE
.1/
Hot-swap fan assembly 1
.2/
Fan assembly 1 LED
.3/
Fan 1 release latch
.4/
Hot-swap fan assembly 2
.5/
Fan assembly 2 LED
.6/
Fan 2 release latch
.7/
Fan Assembly 3 LED
.8/
Fan 3 release latch
.9/
Hot-swap fan assembly 3
To replace a hot-swap fan assembly:
1. Remove the cover. See “Removing the left-side
cover (tower model)” on page 103 or “Removing the
cover (rack model)” on page 104.
Attention
To ensure proper system cooling, do not remove
the top cover for more than 30 minutes during
this procedure.
2. Determine which fan assembly (fan 1
.1/
, fan 2
.4/
,
or fan 3
.9/
) to replace by checking the fan LEDs on
Netfinity 5600 - Type 8664
139
Summary of Contents for 866441Y - Netfinity 5600 - 8664
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 244: ...236 Netfinity Server HMM...
Page 245: ...Related service information 237...
Page 246: ...238 Netfinity Server HMM...
Page 247: ...Related service information 239...
Page 258: ...250 Netfinity Server HMM...
Page 259: ...Related service information 251...
Page 275: ......
Page 276: ...IBM Part Number 09N1595 Printed in U S A S 9N 1595...