PCNTNW-NW-074 The hardware interrupt cannot be set.
Explanation: An attempt was made to initialize a given hardware interrupt.
The attempt was not successful.
Action: If you have an Ethernet adapter installed, make sure the adapter
does not share an IRQ with any other device (see “PCI Slot/Device
Information” on page 35.)
PCNTNW-NW-075 The Multiple Link Interface Driver (MLID) cannot be
registered with the Link Support Layer (LSL).
Explanation: An error occurred while the driver was trying to register with the
LSL.
Action: Check the version of the NetWare or IntraNetWare Operating
System. Make sure that this driver is correct for the version of NetWare or
IntraNetWare that you are using. Restart the server.
PCNTNW-NW-079 The Multiple Link Interface Driver (MLID) did not
initialize MSMTx Free Count.
Explanation: The MSMTx Free Count is not initialized correctly.
Action: Restart the server. If the problem persists, replace the adapter.
PCNTNW-NW-086 The driver parameter block is too small.
Explanation: The driver parameter block is too small.
Action: Restart the server. If the problem persists, replace the adapter.
PCNTNW-NW-087 The media parameter block is too small.
Explanation: The driver media parameter block is too small.
Action: Restart the server. If the problem persists, replace the adapter.
PCNTNW-NW-091 The hardware configuration conflicts.
Explanation: You tried to load a new frame type for the existing controller.
The hardware assumptions made in doing so are incorrect. This error can
also occur if you try to specify a mode (such as, redundancy) that conflicts
with another specified mode.
Action: Make sure that your hardware configuration matches the software
settings. See “PCI Slot/Device Information” on page 35 for information on
viewing and changing interrupt requests.
PCNTNW-NW-126 The group bit in the node address override was
cleared.
Explanation: The IEEE address has a group bit indicating that an address
belongs to a group of stations. This bit is used only as a destination address;
it cannot be used as a source address. You tried to enter a source address
with this bit set. The driver cleared the group bit of the source address.
Action: None necessary, message is for information only.
PCNTNW-NW-127 The local bit in the node address override was set.
Explanation: The local bit in the IEEE address format indicates that the
addresses are being managed locally. If you use the node address override
capabilities of this driver to enter a new address, the local bit must be set.
You entered an address without the local bit set. The driver has set the local
bit.
Action: None necessary, message is for information only.
PCNTNW-NW-164 The device was not found.
Explanation: The driver cannot find an Ethernet controller in the server.
Action: Verify that the Ethernet controller is enabled. (See “PCI Slot/Device
Information” on page 35.) If the Ethernet controller is enabled, go to “General
checkout” on page 6 to run the diagnostic programs.
PCNTNW-NW-165 The device was not found at IOADDRESS.
Explanation: The Ethernet controller cannot be found at the I/O address
specified.
Action: The Ethernet controller does not require a parameter for the I/O
address. Remove the I/O address parameter.
218
Netfinity Server HMM
Summary of Contents for 866441Y - Netfinity 5600 - 8664
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 244: ...236 Netfinity Server HMM...
Page 245: ...Related service information 237...
Page 246: ...238 Netfinity Server HMM...
Page 247: ...Related service information 239...
Page 258: ...250 Netfinity Server HMM...
Page 259: ...Related service information 251...
Page 275: ......
Page 276: ...IBM Part Number 09N1595 Printed in U S A S 9N 1595...