Symptom-to-FRU index
237
Fan error messages
Power error messages
System over temperature for CPU "X"
(level-warning; CPU "X" reporting over temperature
condition)
1.
Ensure system is being properly cooled;
see
“Temperature checkout” on page 31.
2.
Replace CPU "X".
3.
Replace Processor/PCI Board.
System under recommended CPU "X" temperature
(level-warning; system reporting under temperature
condition for CPU "X")
1.
Ambient temperature must be within normal operating
specifications
; (see “Features and specifications” on page
3).
2.
Replace CPU "X".
3.
Replace Processor/PCI Board.
Message
Action
Fan "X" failure
(level-critical; fan "X" had a failure)
1.
Check connections to fan "X"
2.
Replace fan "X"
Fan "X" fault
(level-critical; fan "X" beyond
recommended RPM range)
1.
Check connections to fan "X"
2.
Replace fan "X"
Message
Action
Power supply "X" current fault
(level-critical; excessive
current demand on power supply "X")
1.
See “Power checkout” on page 31.
Power supply "X" DC good fault
(level-critical; power
good signal not detected for power supply "X")
1.
Replace power supply "X"
Power supply "X" fan fault
(level-critical; fan fault in
power supply "X")
1.
Replace power supply "X"
Power supply "X" fault
(level-critical; overcurrent
condition exists)
1.
See “Power checkout” on page 31.
Power supply "X" 12V fault
(level-critical;
overcurrent condition detected)
1.
See “Power checkout” on page 31.
Power supply "X" 3.3V fault
(level-critical;
3.3V power supply "X" had an error)
1.
See “Power checkout” on page 31.
Power supply "X" 5V fault
(level-critical; 5V power supply
"X" had an error)
1.
See “Power checkout” on page 31.
System over recommended "X" current
(level-non-
critical; system running too much current on that voltage)
1.
See “Power checkout” on page 31.
System running non-redundant power
(level-non-
critical; system does not have redundant power)
1.
Add another power supply
2.
Remove options from system
3.
System can continue to operate without redundancy
protection if 1 and 2 above are not followed.
Message
Action
Summary of Contents for 86655RY - Netfinity 7600 - 8665
Page 1: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 2: ......
Page 3: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 10: ...viii Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 52: ...42 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 104: ...94 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 148: ...138 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 252: ...242 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 270: ...260 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 271: ...Related service information 261 ...
Page 272: ...262 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 273: ...Related service information 263 ...
Page 274: ...264 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 284: ...274 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 285: ...Related service information 275 ...
Page 292: ...282 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 293: ......