Diagnostics
19
For example:
Controller 1 Slot 5, Status:Not responding properly - Error Code=0B0
Controller 2 Slot 4, Logical Drive=0, Other=0, Firmware=2.88.10, Status=Ok
Controller 3 Slot 3, Logical Drive=0, Other=0, Firmware=3.60.13, Status=Ok
Controller 4 Slot 2, Logical Drive=1, Other=1, Firmware=1.00.09, Status=Ok
If no errors occur:
ISPR (aaaa) = EF10
BCS (bb) = 0F or 09
ECS (cc) = 00
If an error occurs, refer to: “ServeRAID POST (ISPR) error codes” on page 232 for the
ISPR error codes and “Basic and Extended Configuration Status Register Codes” for
the BCS and ECS error codes.
Basic and Extended Configuration Status Register Codes:
BCS
ECS
Explanation and possible recovery action
Code not in
table
Code not in
table
Explanation:
The ServeRAID controller is not functioning properly.
Action:
Replace the adapter or the I/O board with integrated controller.
00
01
Explanation:
Invalid flash configuration.
Action:
Start the IBM ServeRAID Support CD and follow the instructions that appear
on the screen.
00
02
Explanation:
Invalid NVRAM configuration.
Action:
Start the IBM ServeRAID Support CD and follow the instructions that appear
on the screen.
00
03
Explanation:
Invalid flash and NVRAM configuration.
Action:
Start the IBM ServeRAID Support CD and follow the instructions that appear
on the screen.
01
08
Explanation:
No configuration was found in drives, or online/rebuild drives are not
responding.
Action:
Press F4, F5, F7, or F10.
01
18
Explanation:
No configuration was found in drives, or online/rebuild and hot-
spare/standby hot-spare drives are not responding.
Action:
Press F4, F5, F7, or F10.
01
28
Explanation:
No configuration was found in drives, or online/rebuild and
ready/standby drives are not responding.
Action:
Press F4, F5, F7, or F10.
01
38
Explanation:
No configuration was found in drives, or online/rebuild, hot-
spare/standby hot-spare, and ready/standby drives are not responding.
Action:
Press F4, F5, F7, or F10.
01
48
Explanation:
No configuration was found in drives, or online/rebuild drives are not
responding and unidentified drives were found.
Action:
Press F4, F5, F7, or F10.
Summary of Contents for 86655RY - Netfinity 7600 - 8665
Page 1: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 2: ......
Page 3: ...IBM Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 10: ...viii Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 52: ...42 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 104: ...94 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 148: ...138 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 252: ...242 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 270: ...260 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 271: ...Related service information 261 ...
Page 272: ...262 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 273: ...Related service information 263 ...
Page 274: ...264 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 284: ...274 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 285: ...Related service information 275 ...
Page 292: ...282 Hardware Maintenance Manual Netfinity 7600 Type 8665 Models 1RY 2RY ...
Page 293: ......